update docs

This commit is contained in:
maliakal_d 2020-11-25 16:22:24 +01:00
parent 6901368fd6
commit 8e6dfe9b0f
3 changed files with 22 additions and 162 deletions

View File

@ -1,5 +1,5 @@
SLS Detector Package 5.0.1 released on 18.11.2020 (Bugfix Release)
=================================================================
SLS Detector Package 5.0.1 released on 25.11.2020 (Bug Fix Release)
===================================================================
This document describes the differences between 5.0.1 and 5.0.0 releases.
@ -41,7 +41,7 @@ This document describes the differences between 5.0.1 and 5.0.0 releases.
CMake improvements
------------------
1. Explicitly state Python 3.6 or greater
1. Explicitly state Python 3.6 or greater.
2. Finds the Python of the activated environment when using conda
without having to supply additional arguments.

View File

@ -9,7 +9,7 @@ CMake approaches.
One can test with :ref:`detector simulators<Virtual Detector Servers>` before testing the API with a real detector or when a real detector is not at hand.
CMake: slsDetectorPackage as submodule in your project
---------------------------------------
---------------------------------------------------------------
If you are using CMake to build your integration and want to build everything
in one go, we support adding slsDetectorPackage as a subfolder in your cmake project.

View File

@ -12,32 +12,7 @@ Download
- detector server corresponding to package in slsDetectorPackage/serverBin
- bit files
.. list-table::
:widths: 25 10 30 25 10
:header-rows: 1
* - Software
- Hardware
- Firmware Date
- Firmware Link
- Comments
* - v5.0.0-rcx
-
- 08.09.2020
- `v27 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/eiger/v27/>`__
-
* - v4.0.0 - v4.2.0
-
- 30.07.2019
- `v24 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/eiger/v24/>`__
-
* - v3.1.0 - v3.1.5
-
- 17.08.2017
- `v20 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/eiger/v20/>`__
-
- `bit files <https://github.com/slsdetectorgroup/slsDetectorFirmware>`__
Upgrade
^^^^^^^^
@ -116,37 +91,7 @@ Download
^^^^^^^^^^^^^
- detector server corresponding to package in slsDetectorPackage/serverBin
- pof files
.. list-table::
:widths: 25 10 30 25 10
:header-rows: 1
* - Software
- Hardware
- Firmware Date
- Firmware Link
- Comments
* - v5.0.0-rcx
- 2.0
- 21.07.2020
- `v2.1 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/jungfrau/v2_1/jungfrau_v2_1.pof>`__
-
* - v5.0.0-rcx
- 1.0
- 24.07.2020
- `v1.1 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/jungfrau/v1_1/jungfrau_v1_1.pof>`__
-
* - v4.0.1 - v4.2.0
- 1.0
- 06.12.2018
- `v0.7 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/jungfrau/v0_7/jungfrau_v0_7.pof>`__
-
* - v3.1.0 - v3.1.5
- 1.0
- 13.11.2017
- `v0.6 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/jungfrau/v0_6/jungfrau_v0_6.pof>`__
-
- `pof files <https://github.com/slsdetectorgroup/slsDetectorFirmware>`__
Upgrade (from v4.x.x)
@ -156,7 +101,7 @@ Check :ref:`firmware troubleshooting <blackfin firmware troubleshooting>` if you
#. Tftp must be installed on pc.
#. Update client package to the latest (5.0.0-rc1).
#. Update client package to the latest (5.x.x).
#. Disable server respawning or kill old server
.. code-block:: bash
@ -204,7 +149,7 @@ Check :ref:`firmware troubleshooting <blackfin firmware troubleshooting>` if you
jungfrauDetectorServervxxx --stop-server 1953
Upgrade (from v5.0.0-rcx)
Upgrade (from v5.0.0)
^^^^^^^^^^^^^^^^^^^^^^^^^^
Check :ref:`firmware troubleshooting <blackfin firmware troubleshooting>` if you run into issues while programming firmware.
@ -230,31 +175,8 @@ Download
^^^^^^^^^^^^^
- detector server corresponding to package in slsDetectorPackage/serverBin
- pof files
.. list-table::
:widths: 15 15 15 15 5
:header-rows: 1
- `pof files <https://github.com/slsdetectorgroup/slsDetectorFirmware>`__
* - Software
- Hardware
- Firmware Date
- Firmware Link
- Comments
* - All versions
- 50um
- 08.02.2018
- `50um <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/gotthard_I/50um/gotthard_I_50um.pof>`__
-
* - All versions
- 25um (master)
- 08.02.2018
- `25um (master) <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/gotthard_I/25um/master/gotthard_I_25um_master.pof>`__
-
* - All versions
- 25um (slave)
- 09.02.2018
- `25um (slave) <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/gotthard_I/25um/slave/gotthard_I_25um_slave.pof>`__
-
.. _firmware upgrade using blaster for blackfin:
@ -294,24 +216,10 @@ Download
- detector server corresponding to package in slsDetectorPackage/serverBin
- rbf files
.. list-table::
:widths: 25 10 30 25 10
:header-rows: 1
* - Software
- Hardware
- Firmware Date
- Firmware Link
- Comments
* - v5.0.0-rcx
-
- 25.09.2020
-
- development
- rbf files (in developement)
Upgrade (from v5.0.0-rcx)
Upgrade (from v5.0.0)
^^^^^^^^^^^^^^^^^^^^^^^^^^^
#. Program from console
@ -337,23 +245,10 @@ Download
^^^^^^^^^^^^^
- detector server corresponding to package in slsDetectorPackage/serverBin
- rbf files
.. list-table::
:widths: 25 10 30 25 10
:header-rows: 1
- rbf files (in development)
* - Software
- Hardware
- Firmware Date
- Firmware Link
- Comments
* - v5.0.0-rcx
-
- 25.09.2020
-
- development
Upgrade (from v5.0.0-rcx)
Upgrade (from v5.0.0)
^^^^^^^^^^^^^^^^^^^^^^^^^^
#. Program from console
@ -375,28 +270,10 @@ Download
^^^^^^^^^^^^^
- detector server corresponding to package in slsDetectorPackage/serverBin
- pof files
.. list-table::
:widths: 25 10 30 25 10
:header-rows: 1
- `pof files <https://github.com/slsdetectorgroup/slsDetectorFirmware>`__
* - Software
- Hardware
- Firmware Date
- Firmware Link
- Comments
* - v5.0.0-rcx
- EPCQ128
- 05.10.2020
- `v1.0 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/moench/EPCQ128/v1_0/moench_v1_0_201005.pof>`__
-
* - v5.0.0-rcx
- EPCS128
- 05.10.2020
- `v1.0 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/moench/EPCS128/v1_0/moench_v1_0_201005.pof>`__
-
Upgrade (from v5.0.0-rcx)
Upgrade (from v5.0.0)
^^^^^^^^^^^^^^^^^^^^^^^^^^^
Check :ref:`firmware troubleshooting <blackfin firmware troubleshooting>` if you run into issues while programming firmware.
@ -419,28 +296,10 @@ Download
^^^^^^^^^^^^^
- detector server corresponding to package in slsDetectorPackage/serverBin
- pof files
.. list-table::
:widths: 25 10 30 25 10
:header-rows: 1
- `pof files <https://github.com/slsdetectorgroup/slsDetectorFirmware>`__
* - Software
- Hardware
- Firmware Date
- Firmware Link
- Comments
* - v5.0.0-rcx
- EPCQ128
- 05.10.2020
- `v1.0 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/ctb/EPCQ128/v1_0/ctb_v1_0_201005.pof>`__
-
* - v5.0.0-rcx
- EPCS128
- 05.10.2020
- `v1.0 <https://github.com/slsdetectorgroup/slsDetectorFirmware/blob/master/binaries/ctb/EPCS128/v1_0/ctb_v1_0_201005.pof>`__
-
Upgrade (from v5.0.0-rcx)
Upgrade (from v5.0.0)
^^^^^^^^^^^^^^^^^^^^^^^^^^
Check :ref:`firmware troubleshooting <blackfin firmware troubleshooting>` if you run into issues while programming firmware.
@ -462,11 +321,12 @@ Check :ref:`firmware troubleshooting <blackfin firmware troubleshooting>` if you
Firmware Troubleshooting with blackfin
----------------------------------------
#. v4.x.x client after programming will most likely reboot the blackfin processor, regardless of error.
1. v4.x.x client after programming will most likely reboot the blackfin processor, regardless of error.
#. v5.x.x-rcx client after programming will not reboot the blackfin processor, if error occurred.
2. v5.x.x-rcx client after programming will not reboot the blackfin processor, if error occurred.
3. If a reboot occured with an incomplete firmware in flash, the blackfin will most likely not find the mtd3 drive. To see if this drive exists:
#. If a reboot occured with an incomplete firmware in flash, the blackfin will most likely not find the mtd3 drive. To see if this drive exists:
.. code-block:: bash
# connect to the board
@ -482,7 +342,7 @@ Firmware Troubleshooting with blackfin
4. If one can see the mtd3 drive, one can already try to flash again using the **programfpga** command (without rebooting blackfin or detector).
#. If one can't list it, read the next section to try to get the blackfin to list it.
5. If one can't list it, read the next section to try to get the blackfin to list it.
How to get back mtd3 drive remotely
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^