mirror of
https://github.com/slsdetectorgroup/slsDetectorPackage.git
synced 2025-06-23 10:07:59 +02:00
changing command from vhighvoltage to highvoltage
This commit is contained in:
@ -335,7 +335,7 @@ Advanced settings changing the analog or digital performance of the acquisition.
|
||||
\item[vpreamp n] Sets the DAC value of the preamp feedback to n.
|
||||
\item[vshaper1 n] Sets the DAC value of the shaper1 feedback to n.
|
||||
\item[vshaper2 n] Sets the DAC value of the shaper2 feedback to n.
|
||||
\item[vhighvoltage n] Sets the DAC value of the high voltage to n (in V).
|
||||
\item[highvoltage n] Sets the DAC value of the high voltage to n (in V).
|
||||
\item[vapower n] CHIPTEST BOARD ONLY - Sets the DAC value of the analog voltage to n.
|
||||
\item[vddpower n] CHIPTEST BOARD ONLY - Sets the DAC value of the analog voltage to n.
|
||||
\item[vshpower n] CHIPTEST BOARD ONLY - Sets the comparator power supply in dac units (0-1024).
|
||||
@ -648,7 +648,7 @@ Advanced settings changing the analog or digital performance of the acquisition.
|
||||
\item[vpreamp] Returns the DAC value of the preamp feedback to n.
|
||||
\item[vshaper1] Returns the DAC value of the shaper1 feedback to n.
|
||||
\item[vshaper2] Returns the DAC value of the shaper2 feedback to n.
|
||||
\item[vhighvoltage] Returns the DAC value of the high voltage to n.
|
||||
\item[highvoltage] Returns the DAC value of the high voltage to n.
|
||||
\item[vapower] CHIPTEST BOARD ONLY - Returns the DAC value of the analog voltage to n.
|
||||
\item[vddpower] CHIPTEST BOARD ONLY - Returns the DAC value of the analog voltage to n.
|
||||
\item[vshpower] CHIPTEST BOARD ONLY - Returns the comparator power supply in dac units (0-1024).
|
||||
@ -714,7 +714,7 @@ One can configure all the detector settings in a parameter file {\tt{setup.det}}
|
||||
sls_detector_put parameters setup.det
|
||||
\end{verbatim}
|
||||
|
||||
In the case of \E, the parameter file ({\tt{setup.det}} needs to setup the proper bias voltage of the sensor, i.e. needs to contain the line {\tt{vhighvoltage 150}}.
|
||||
In the case of \E, the parameter file ({\tt{setup.det}} needs to setup the proper bias voltage of the sensor, i.e. needs to contain the line {\tt{highvoltage 150}}.
|
||||
|
||||
\subsection{Standard acquisition}
|
||||
|
||||
|
Reference in New Issue
Block a user