mirror of
https://github.com/slsdetectorgroup/slsDetectorPackage.git
synced 2026-01-22 18:33:16 +01:00
release notes
This commit is contained in:
29
RELEASE.txt
29
RELEASE.txt
@@ -1,10 +1,9 @@
|
|||||||
SLS Detector Package Patch Release 6.1.2 released on 14.11.2022
|
SLS Detector Package Patch Release 6.1.2 released on 25.11.2022
|
||||||
===============================================================
|
===============================================================
|
||||||
|
|
||||||
This document describes the differences between v6.1.2 and v6.1.1.
|
This document describes the differences between v6.1.2 and v6.1.1.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
CONTENTS
|
CONTENTS
|
||||||
--------
|
--------
|
||||||
1. Resolved Issues
|
1. Resolved Issues
|
||||||
@@ -22,6 +21,7 @@ This document describes the differences between v6.1.2 and v6.1.1.
|
|||||||
---------------
|
---------------
|
||||||
|
|
||||||
1. [Jungfrau, Moench, Ctb]
|
1. [Jungfrau, Moench, Ctb]
|
||||||
|
Programming Firmware
|
||||||
Updating kernel was not enough to ensure seamless programming of FPGA.
|
Updating kernel was not enough to ensure seamless programming of FPGA.
|
||||||
nCe signal now made high before programming blackfin.
|
nCe signal now made high before programming blackfin.
|
||||||
|
|
||||||
@@ -66,6 +66,29 @@ This document describes the differences between v6.1.2 and v6.1.1.
|
|||||||
between the modules and set it to the max + 1 to ensure that they
|
between the modules and set it to the max + 1 to ensure that they
|
||||||
all start with the same frame number for the next acquisition.
|
all start with the same frame number for the next acquisition.
|
||||||
|
|
||||||
|
Client
|
||||||
|
------
|
||||||
|
|
||||||
|
1. [Eiger] Stop command freezes server
|
||||||
|
It is apparent in large detectors.
|
||||||
|
|
||||||
|
For example, if module A got a "stop" during an acquisition,
|
||||||
|
it stops to an 'Idle' state. If module B gets a "stop" before an
|
||||||
|
acquisition, it will return it is in 'Idle' state and continue
|
||||||
|
to start the next acquisition, but module B then waits for "ready
|
||||||
|
for trigger" synchronization from module A, which it will never get.
|
||||||
|
|
||||||
|
Since module B missed the asynchronous stop command, the workaround
|
||||||
|
in the client is to send another "stop" command (upto 10 retries)
|
||||||
|
till it returns Idle.
|
||||||
|
|
||||||
|
2. [Eiger][Jungfrau][Moench][Ctb]
|
||||||
|
Stop results in different frame numbers
|
||||||
|
A "stop" command will also now check for inconsistent 'nextframenumber'
|
||||||
|
between the modules and set it to the max + 1 to ensure that they
|
||||||
|
all start with the same frame number for the next acquisition.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
2. On-board Detector Server Compatibility
|
2. On-board Detector Server Compatibility
|
||||||
==========================================
|
==========================================
|
||||||
@@ -89,12 +112,12 @@ This document describes the differences between v6.1.2 and v6.1.1.
|
|||||||
https://slsdetectorgroup.github.io/devdoc/serverupgrade.html
|
https://slsdetectorgroup.github.io/devdoc/serverupgrade.html
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
3. Firmware Requirements
|
3. Firmware Requirements
|
||||||
========================
|
========================
|
||||||
|
|
||||||
Note: No change to 6.1.1.
|
Note: No change to 6.1.1.
|
||||||
|
|
||||||
|
|
||||||
Eiger
|
Eiger
|
||||||
=====
|
=====
|
||||||
Compatible version : 08.10.2021 (v29)
|
Compatible version : 08.10.2021 (v29)
|
||||||
|
|||||||
Reference in New Issue
Block a user