diff --git a/manual/slsDetectorClientDocs/html/settings.html b/manual/slsDetectorClientDocs/html/settings.html
index e63bd11c8..53898761c 100644
--- a/manual/slsDetectorClientDocs/html/settings.html
+++ b/manual/slsDetectorClientDocs/html/settings.html
@@ -40,6 +40,15 @@ var searchBox = new SearchBox("searchBox", "search",false,'Search');
Commands to setup the settings of the detector
+
+commands to setup settings/trim/cal directories
+
- settingsdir [dir] Sets/gets the directory where the settings files are located (string)
@@ -51,6 +60,9 @@ var searchBox = new SearchBox("searchBox", "search",false,'Search');
- trimen [n e0 e1...e(n-1)] Sets/gets the number of energies n at which the detector has default trim file and their values in eV (int)
+
+commands to configure settings and threshold of detector
- settings [s] sets/gets the settings of the detector. Options:
standard
, fast
, highgain
, dynamicgain
, lowgain
, mediumgain
, veryhighgain
, lownoise
, dynamichg0
, fixgain1
, fixgain2
, forceswitchg1
, forceswitchg2
.
In Eiger, only sets in client shared memory. Use threshold
or thresholdnotb
to pass to detector. Gets from detector.
@@ -73,6 +85,9 @@ var searchBox = new SearchBox("searchBox", "search",false,'Search');
- pedestal [i] starts acquisition for i frames, calculates pedestal and writes back to fpga. Used in GOTTHARD only. Only put!
+
+commands to configure DACs of detector
- vthreshold [i] [mv] Sets/gets detector threshold voltage for single photon counters. Normally in DAC units unless
mv
is specified at the end of the command line (int)
@@ -211,6 +226,9 @@ var searchBox = new SearchBox("searchBox", "search",false,'Search');
- v_limit [i] mv Sets/gets a soft limit for the power supplies and the DACs on the new chiptest board. Must be in mV (int)
+
+commands to readout ADCs of detector
- temp_adc Gets the ADC temperature (int)
diff --git a/manual/slsDetectorClientDocs/latex/doxygen.sty b/manual/slsDetectorClientDocs/latex/doxygen.sty
index 5e70890f8..b138dbe41 100644
--- a/manual/slsDetectorClientDocs/latex/doxygen.sty
+++ b/manual/slsDetectorClientDocs/latex/doxygen.sty
@@ -24,9 +24,9 @@
\fancyplain{}{\bfseries\thepage}%
}
\rfoot[\fancyplain{}{\bfseries\scriptsize%
- Generated on Thu Aug 17 13:55:05 2017 by Doxygen }]{}
+ Generated on Thu Aug 17 14:16:02 2017 by Doxygen }]{}
\lfoot[]{\fancyplain{}{\bfseries\scriptsize%
- Generated on Thu Aug 17 13:55:05 2017 by Doxygen }}
+ Generated on Thu Aug 17 14:16:02 2017 by Doxygen }}
\cfoot{}
%---------- Internal commands used in this style file ----------------
diff --git a/manual/slsDetectorClientDocs/latex/refman.tex b/manual/slsDetectorClientDocs/latex/refman.tex
index b07c6d8a6..9c75cbda8 100644
--- a/manual/slsDetectorClientDocs/latex/refman.tex
+++ b/manual/slsDetectorClientDocs/latex/refman.tex
@@ -40,7 +40,7 @@
\vspace*{1cm}
{\large Generated by Doxygen 1.6.1}\\
\vspace*{0.5cm}
-{\small Thu Aug 17 13:55:05 2017}\\
+{\small Thu Aug 17 14:16:02 2017}\\
\end{center}
\end{titlepage}
\pagenumbering{roman}
diff --git a/manual/slsDetectorClientDocs/latex/settings.tex b/manual/slsDetectorClientDocs/latex/settings.tex
index 6cbffeda8..5ce2d57cd 100644
--- a/manual/slsDetectorClientDocs/latex/settings.tex
+++ b/manual/slsDetectorClientDocs/latex/settings.tex
@@ -1,4 +1,11 @@
Commands to setup the settings of the detector
+\begin{DoxyItemize}
+\item \hyperlink{settings_settingsdir}{Settings, trim \& cal Directories}: commands to setup settings/trim/cal directories
+\item \hyperlink{settings_settingssett}{Settings and Threshold}: commands to configure settings and threshold of detector
+\item \hyperlink{settings_settingsdacs}{DACs}: commands to configure DACs of detector
+\item \hyperlink{settings_settingsadcs}{ADCs}: commands to readout ADCs of detector
+\end{DoxyItemize}\hypertarget{settings_settingsdir}{}\subsection{Settings, trim \& cal Directories}\label{settings_settingsdir}
+commands to setup settings/trim/cal directories
\begin{DoxyItemize}
@@ -18,7 +25,8 @@ Commands to setup the settings of the detector
\begin{DoxyItemize}
\item {\bfseries trimen \mbox{[}n e0 e1...e(n-\/1)\mbox{]}} Sets/gets the number of energies n at which the detector has default trim file and their values in eV (int)
-\end{DoxyItemize}
+\end{DoxyItemize}\hypertarget{settings_settingssett}{}\subsection{Settings and Threshold}\label{settings_settingssett}
+commands to configure settings and threshold of detector
\begin{DoxyItemize}
@@ -54,7 +62,8 @@ Commands to setup the settings of the detector
\begin{DoxyItemize}
\item {\bfseries pedestal \mbox{[}i\mbox{]}} starts acquisition for i frames, calculates pedestal and writes back to fpga. Used in GOTTHARD only. Only put!
-\end{DoxyItemize}
+\end{DoxyItemize}\hypertarget{settings_settingsdacs}{}\subsection{DACs}\label{settings_settingsdacs}
+commands to configure DACs of detector
\begin{DoxyItemize}
@@ -284,7 +293,8 @@ Commands to setup the settings of the detector
\begin{DoxyItemize}
\item {\bfseries v\_\-limit \mbox{[}i\mbox{]} mv} Sets/gets a soft limit for the power supplies and the DACs on the new chiptest board. Must be in mV (int)
-\end{DoxyItemize}
+\end{DoxyItemize}\hypertarget{settings_settingsadcs}{}\subsection{ADCs}\label{settings_settingsadcs}
+commands to readout ADCs of detector
\begin{DoxyItemize}