* slsSupportLib done, at receiver rooting out in implementation * removed from receiver and client * removed everywhere except gui, python and client(commands.yaml and Detector.h) * updated python * fixed autocomplete to print what the issue is if there is one with ToString when running the autocomplete script to generate fixed.json. updated readme.md in generator folder * formatting * removed enums for dacs * udpating autocomplete and generating commands * removed gotthard from docs and release notes * removed dac test * bug from removing g1 * fixed virtual test for xilinx, was minor. so in this PR * gui done * binary in merge fix * formatting and removing enums * updated fixed and dump.json * bash autocomplete * updated doc on command line generation * removing increments in dac enums for backward compatibility. Not required * removed ROI from rxParameters (only in g1), not needed to be backward compatible * removed the phase shift option from det server staruip
This commit is contained in:
@ -131,42 +131,6 @@ Program from console
|
||||
|
||||
|
||||
|
||||
Gotthard I
|
||||
-----------
|
||||
|
||||
Download
|
||||
^^^^^^^^^^^^^
|
||||
- detector server corresponding to package in slsDetectorPackage/serverBin
|
||||
|
||||
- `pof files <https://github.com/slsdetectorgroup/slsDetectorFirmware>`__
|
||||
|
||||
|
||||
.. _firmware upgrade using blaster for blackfin:
|
||||
|
||||
Upgrade
|
||||
^^^^^^^^
|
||||
.. warning ::
|
||||
| Gotthard firmware cannot be upgraded remotely and requires the use of USB-Blaster.
|
||||
| It is generally updated by us.
|
||||
|
||||
#. Download `Altera Quartus software or Quartus programmer <https://fpgasoftware.intel.com/20.1/?edition=standard&platform=linux&product=qprogrammer#tabs-4>`__.
|
||||
|
||||
|
||||
#. Start Quartus programmer, click on Hardware Setup. In the "Currently selected hardware" window, select USB-Blaster.
|
||||
|
||||
#. In the Mode combo box, select "Active Serial Programming".
|
||||
|
||||
#. Plug the end of your USB-Blaster with the adaptor provided to the connector 'AS config' on the Gotthard board.
|
||||
|
||||
#. Click on 'Add file'. Select programming (pof) file provided by us.
|
||||
|
||||
#. Check "Program/Configure" and "Verify". Push the start button. Wait until the programming process is finished.
|
||||
|
||||
#. In case of error messages, check the polarity of cable (that pin1 corresponds) and that the correct programming connector is selected.
|
||||
|
||||
#. Reboot the detector.
|
||||
|
||||
|
||||
Mythen III
|
||||
-----------
|
||||
|
||||
@ -396,7 +360,3 @@ How to get back mtd3 drive remotely (udpating kernel)
|
||||
more /proc/mtd # verify mtd3 is listed
|
||||
|
||||
|
||||
Last Resort using USB Blaster
|
||||
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||
|
||||
If none of these steps work, the last resort might be physically upgrading the firmware using a USB blaster, which also requires opening up the detector. Instructions for all the blackfin detectors are the same as the one for :ref:`gotthard firmware upgrade <firmware upgrade using blaster for blackfin>`.
|