included number of triggers for number of measurements, script and parameters work for non scan types

git-svn-id: file:///afs/psi.ch/project/sls_det_software/svn/slsDetectorGui@20 af1100a4-978c-4157-bff7-07162d2ba061
This commit is contained in:
l_maliakal_d
2012-07-24 15:39:36 +00:00
parent 3b59d03526
commit 111608bdc8
10 changed files with 501 additions and 182 deletions

View File

@ -634,10 +634,14 @@ void qTabMeasurement::setTimingMode(int mode){
#endif
}
/** To reconnect all the signals after changing their values*/
Initialization(1);
// to let qdrawplot know that triggers or frames are used
myPlot->setFrameEnabled(lblNumTriggers->isEnabled());
myPlot->setTriggerEnabled(lblNumFrames->isEnabled());
return;
}
@ -654,6 +658,11 @@ void qTabMeasurement::Refresh(){
lblProgressIndex->setText(QString::number(myDet->getFileIndex()));
/** Timing mode**/
SetupTimingMode();
// to let qdrawplot know that triggers or frames are used
myPlot->setFrameEnabled(lblNumTriggers->isEnabled());
myPlot->setTriggerEnabled(lblNumFrames->isEnabled());
}