scripts and setup to run version 1 of the jungfrau calibration CuFDBCS = copper fluorescence, direct beam, current source Module 006 - ESRF ./JFMC_CuFluoPeak 006 /mnt/pcmoench_jungfrau_data/Module_006_161116 10us_500Hz_QS_allgain_pede 10us_500Hz_QS_G0_Cu ./JFMC_CuFluoPeakFit 006 ./JFMC_DirectBeamScan 006 /mnt/pcmoench_jungfrau_data/Module_006_161116 100us_500Hz_QS_allgain_pede_1055 100us_500Hz_QS_beam_scan_a ./JFMC_CurrentSourceScan 006 /mnt/pcmoench_jungfrau_data/Module_006_161116 Current_source_scan_a ./JFMC_CalibWriter 006 Module 008 - Pohang ./JFMC_CuFluoPeak 008 /mnt/pcmoench_jungfrau_data/Module_008_181116 10us_500Hz_QS_allgain_pede_1558 10us_500Hz_QS_G0_Cu_2 ./JFMC_CuFluoPeakFit 008 ./JFMC_DirectBeamScan 008 /mnt/pcmoench_jungfrau_data/Module_008_181116 150us_500Hz_QS_allgain_pede_1332 150us_500Hz_QS_beam_scan_b ./JFMC_CurrentSourceScan 008 /mnt/pcmoench_jungfrau_data/Module_008_181116 Current_source_scan_a ./JFMC_CalibWriter 008 Module 021 - 1M top LCLS, PX ./JFMC_CuFluoPeak 021 /mnt/pcmoench_jungfrau_data/1M_021_022_150916 10us_200Hz_QS_allgain_pede__B 10us_200Hz_QS_G0_Cu__B ./JFMC_CuFluoPeakFit 021 ./JFMC_DirectBeamScan 021 /mnt/pcmoench_jungfrau_data/1M_021_022_150916 200us_200Hz_QS_allgain_pede_scan_d_B 200us_200Hz_QS_beam_scan_d_B ./JFMC_CurrentSourceScan 021 /mnt/pcmoench_jungfrau_data/1M_021_022_150916 Current_source_scan_a_B ./JFMC_CalibWriter 021 Module 022 - 1M bottom LCLS, PX ./JFMC_CuFluoPeak 022 /mnt/pcmoench_jungfrau_data/1M_021_022_150916 10us_200Hz_QS_allgain_pede__A 10us_200Hz_QS_G0_Cu__A ./JFMC_CuFluoPeakFit 022 ./JFMC_DirectBeamScan 022 /mnt/pcmoench_jungfrau_data/1M_021_022_150916 200us_200Hz_QS_allgain_pede_scan_d_A 200us_200Hz_QS_beam_scan_d_A ./JFMC_CurrentSourceScan 022 /mnt/pcmoench_jungfrau_data/Module_022_Calib CS_HS_NF_200Hz_scan1 ./JFMC_CalibWriter 022 Module 027 - old HDI (no current source scan). sent to ESRF with Paolo ./JFMC_CuFluoPeak 027 /mnt/pcmoench_jungfrau_data/Module_027_Calib FCu_40kvp_60mA_10us_500Hz_QS_pede FCu_40kvp_60mA_10us_500Hz_QS_beam ./JFMC_CuFluoPeakFit 027 ./dummyRootFileMaker Module 040 - partly etched. sent to ESRF with Paolo ./JFMC_CuFluoPeak 040 /mnt/pcmoench_jungfrau_data/Module_040_Calib Cu_FLuo_240317_500Hz_10us_QS_pede Cu_FLuo_240317_500Hz_10us_QS_beam ./JFMC_CuFluoPeakFit 040 ./JFMC_CurrentSourceScan 040 /mnt/pcmoench_jungfrau_data/Module_040_Calib CS_240322_scan Module 044 - added to the 1M to make the 1.5M, cSAXS ./JFMC_CuFluoPeak 044 /mnt/pcmoench_jungfrau_data/Module044 allpede_10us_500Hz_QS_G0_1500 CuFluo_10us_500Hz_QS_G0 ./JFMC_CuFluoPeakFit 044 ./JFMC_DirectBeamScan 044 /mnt/pcmoench_jungfrau_data/Module044 allpede_150us_500Hz_QS_1620 DB_170221_scan1 ./JFMC_CurrentSourceScan 044 /mnt/pcmoench_jungfrau_data/Module044 CS_170221_scan2 ./JFMC_CalibWriter 044 Module 045 - replaces M021 in the 1M ./JFMC_CuFluoPeak 045 /mnt/pcmoench_jungfrau_data/Module_045_Calib pede_G0_1649_HS_NF_500Hz Cu_HS_NF_500Hz ./JFMC_CuFluoPeakFit 045 ./JFMC_CurrentSourceScan 045 /mnt/pcmoench_jungfrau_data/Module_045_Calib CS_HS_NF_200Hz_scan10 Module 028 direct beam scan data only ./JFMC_DirectBeamScan 028 /mnt/pcmoench_jungfrau_data/test_module028_direct_beam_scan__01092016 200us_scan_a_pedestal_QS 200us_scan_a_beam_QS Module 032 current source scan data only ./JFMC_CurrentSourceScan 032 /mnt/pcmoench_jungfrau_data/test_module032_cal_source_15082016 test_currentsourcescan_5