function varargout = mcamontimer(varargin)
%MCAMONTIMER - Controls the initialisation and termination of the MATLAB
% timer used to poll the MCA monitor command queue.
%
% Started = mcamontimer - returns 1 if monitor polling has been started
% returns 0 if monitor polling has not been started
%
% mcamontimer('start') - starts the timer polling every 0.1 seconds
% mcamontimer('stop') - stops the timer
%
% Notes:
% (1) If monitors are installed using mcamon but mcaTimer has not been
% started, the monitor events will queue up indefinitely. There is
% no limit to the size of the queue, so eventually you will
% run out of memory and crash.
% (2) A polling period of 0.1 seconds is used. This may be varied if
% desired by modifying the 'Period' argument in the definition of
% mcaTimer.
% (3) Call mcamontimer('start') once.
%
% See also MCAMON, MCAMONEVENTS, MCACACHE, MCACLEARMON
%
persistent mcaTimer TimerStarted;
%mocha('test')
if (nargin == 0)
if (TimerStarted)
varargout{1} = 1;
else
varargout{1} = 0;
end
elseif (nargin == 1)
switch varargin{1}
case 'start'
if (TimerStarted)
error('MCA monitor polling is already started.');
end
mlock;
%mcaTimer = timer('TimerFcn', 'mca(600)', 'Period', 0.1, 'ExecutionMode', 'fixedSpacing');
mcaTimer = timer('TimerFcn', 'mocha(402)', 'Period', 10.1, 'ExecutionMode', 'fixedSpacing');
%%mcaTimer.TimerFcn= {@mocha, 'monitorflushevent'};
start (mcaTimer);
TimerStarted = 1;
case 'stop'
if (TimerStarted)
munlock;
stop (mcaTimer);
clear mcaTimer;
TimerStarted = 0;
else
error('MCA monitor polling has not been started.');
end
otherwise
error('Invalid parameter specified for mcamontimer. Use ''start'' or ''stop''.')
end
else
error('Invalid number of arguments in mcamontimer.')
end