mirror of
https://github.com/bec-project/ophyd_devices.git
synced 2026-02-05 14:48:41 +01:00
fix(undulator): add check for operator control for stop_signal
This commit is contained in:
@@ -49,6 +49,14 @@ def test_instant_completion_within_deadband(
|
||||
|
||||
def test_undulator_raises_when_disabled(mock_undulator):
|
||||
mock_undulator.select_control._read_pv.mock_data = 0
|
||||
with pytest.raises(Exception) as e:
|
||||
with pytest.raises(PermissionError) as e:
|
||||
mock_undulator.move(5)
|
||||
assert e.match("Undulator is operator controlled!")
|
||||
|
||||
|
||||
def test_undulator_stop_call(mock_undulator):
|
||||
mock_undulator.select_control._read_pv.mock_data = 1
|
||||
mock_undulator.stop()
|
||||
mock_undulator.select_control._read_pv.mock_data = 0
|
||||
with pytest.raises(PermissionError) as e:
|
||||
mock_undulator.stop()
|
||||
|
||||
Reference in New Issue