fix(flomni): comment out omny_panda_continuous, enabled:false wasn't enough
Both omny_panda and omny_panda_continuous ended up connected and active
simultaneously against the same physical PandA, even though only
omny_panda was enabled: true -- a device already connected apparently
doesn't disconnect just because a later config reload disables it.

Comment the inactive mode's block out entirely instead of relying on
enabled: false, so BEC never constructs the device object at all. Docs
updated to correct the earlier (wrong) guidance that toggling enabled
alone was sufficient to switch between modes.