Files
csaxs_bec/omny_e2e_tests
x01dcandClaude Sonnet 5 7e8e807adc fix(flomni): stop duplicate 360deg tomo angles, add sample owner, fix abort crash
Three independent fixes:

- sub_tomo_scan(): in 360-degree tomo_type-1 mode, every sub-tomogram used
  to sweep the full 0-360 range, so each one's own fine grid contained
  angle pairs exactly 180deg apart -- redundant tomographic information.
  Sub-tomograms now each cover a 180deg span, split into low/high halves
  by subtomo_number % 4 with a bit-reversal-of-4 phase table, so adjacent
  pairs (1,2)/(3,4)/(5,6)/(7,8), either quartet, and all 8 combined each
  independently form a complete, evenly-spaced 360deg tomogram at
  successively finer spacing. Total projection count for a given
  tomo_angle_stepsize is now identical between 180 and 360 mode (same N,
  no longer doubled). Updated the 4 other consumers of the old N/step
  formula (zero-deg reference gating, _tomo_type1_actual_grid, the
  parameter wizard, the PDF report) to match. 180-degree mode is
  unchanged. Live-verified against the running flomni sim: real motor
  motion traces the expected boustrophedon path with no duplicate or
  180deg-apart angles.

- Sample storage: added an owner field, packed into the same EPICS DESC
  field as the sample name ("name | owner", via new sample_desc_codec.py)
  since there's no separate PV for it. Wired through
  FlomniSampleStorage, the CLI (flomni_modify_storage_non_interactive,
  ftransfer_modify_storage), the two transfer routines that forward a
  raw DESC value across a gripper move (now unpacked/repacked so owner
  survives the move instead of being dropped or double-packed), and
  SampleStorageWidget. Scoped to flomni only this session; OMNY's
  storage/transfer mixin is unchanged.

- ConsoleButtonsWidget's ABORT button used to send SIGINT then, 500ms
  later, a stop_devices() broadcast to ALL devices with no stop_id --
  an un-suppressed error from that broadcast landing on a queue-tracked
  instruction could kill the scan worker thread outright, requiring a
  full BEC restart. Replaced with: queue.request_scan_abortion() (safe
  no-op if idle, but registers a stop_id so expected errors are
  suppressed), then SIGINT, then a direct, immediate Galil hard stop via
  new GalilController.hard_abort_and_restore_positioning_mode() -- the
  same method ftransfer_abort() now delegates to, so the CLI and GUI
  paths can't drift apart again. SIGINT is sent before the hard stop:
  live testing showed that if the hard stop's mntprgs-clearing side
  effect lands first, a same-session polling loop can mistake it for
  normal completion and fall through into ensure_gripper_up(), which
  must not happen mid-transfer -- sending SIGINT first (near-instant)
  gives that loop's own KeyboardInterrupt handler a head start before
  the hard stop's own multi-step sequence completes. The button is
  labeled per beamline (e.g. "Flomni Motion Stop") and disabled rather
  than silently inert when no hard-stop device is configured/enabled.
  Scoped to flomni only this session (OMNY/LamNI wiring deferred).
  Live-verified against the running sim, including the exact
  stop-lands-mid-queued-instruction scenario that previously crashed
  the scan worker.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-15 07:09:40 +02:00
..