CI for csaxs_bec / test (push) Successful in 2m35s
flomni already has this (type-1-only: a dedicated projection at exactly 0 degrees before every odd/forward sub-tomogram, plus once more at the end, for tracking radiation damage over a tomogram). Deliberately excluded from OMNY during the Phase 1 port as flomni-specific; Mirko asked for it to be extended to OMNY's generalized equally-spaced types (1/4/5, 2/4/8 sub-tomograms), and confirmed the pre-shot should fire even for sub-tomogram 1 (whose own first projection already lands on 0) to get two consecutive 0-degree shots as an immediate baseline pair. Also fixes a second hardcoded `tomo_type != 1` bug in the widget's _irrelevant_params_for_type() (same class as the earlier _validate() fix) that would have hidden this setting from OMNY type-4/5 job tooltips even when enabled. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01QLrD7sVYGLAzsQjLVJpCgt