x01dcandClaude Sonnet 5 78f0c8fa3b
CI for csaxs_bec / test (push) Successful in 2m35s
feat(omny): port zero_deg_reference_at_each_subtomo to types 1/4/5
flomni already has this (type-1-only: a dedicated projection at exactly
0 degrees before every odd/forward sub-tomogram, plus once more at the
end, for tracking radiation damage over a tomogram). Deliberately
excluded from OMNY during the Phase 1 port as flomni-specific; Mirko
asked for it to be extended to OMNY's generalized equally-spaced types
(1/4/5, 2/4/8 sub-tomograms), and confirmed the pre-shot should fire
even for sub-tomogram 1 (whose own first projection already lands on 0)
to get two consecutive 0-degree shots as an immediate baseline pair.

Also fixes a second hardcoded `tomo_type != 1` bug in the widget's
_irrelevant_params_for_type() (same class as the earlier _validate()
fix) that would have hidden this setting from OMNY type-4/5 job
tooltips even when enabled.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01QLrD7sVYGLAzsQjLVJpCgt
2026-09-03 16:25:07 +02:00
..
2026-06-24 12:55:32 +02:00