Files
csaxs_bec/tests
x01dcandClaude Sonnet 5 70696756f1
CI for csaxs_bec / test (push) Successful in 1m51s
fix(omny): stop polling sample name via a device_rpc queue round-trip
OMNY_TomoParams's poll timer called sample_name_getter every tick,
which for OMNY was dev.omny_samples.get_sample_name_in_samplestage()
-- a device method, dispatched by BEC as a device_rpc request through
the scan queue rather than a local read. With the queue busy or
paused this blocked the widget's Qt thread (GUI freeze while a scan
ran) and piled up duplicate PENDING device_rpc entries in BEC's
primary queue (confirmed live via bec.queue.queue_storage
.describe_queue()). The method was just a one-line wrapper around an
already-readable EpicsSignal, so read it directly with cached=True
instead, matching flomni's fast-getter pattern and avoiding even the
signal round-trip. Also applied cached=True to flomni's own getter,
which didn't have the device_rpc bug but is polled the same way.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01QLrD7sVYGLAzsQjLVJpCgt
2026-09-03 15:52:52 +02:00
..
2026-06-24 12:55:32 +02:00