CI for csaxs_bec / test (push) Successful in 1m45s
The "Enter authorization code" (x12sa) prompt gating advanced tomo modes (types 2-5) predates the account-based _SUPERUSER_ACCOUNTS gate added earlier this branch, and is now fully redundant with it -- Mirko asked to remove it. Each mode still prints the existing "significant wear" warning unconditionally instead of only after entering the code. Also added a hard 2.5 degree ceiling on tomo type 3's angular step (golden ratio starting angle mode), replacing its old minimum-100-projections floor with an explicit wear-motivated cap; if the requested projection count implies a larger step, it's clamped down to 2.5 degrees. Type 2's golden_ratio_bunch_size minimum stays at 100 per Mirko's call -- wear avoidance there is handled by the warning message, not a lower floor. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01QLrD7sVYGLAzsQjLVJpCgt