fix(flomni): reset tomo progress before pre-flight gates, not after
tomo_scan() only reset the progress dict (projection/subtomo/angle/
tomo_start_time/heartbeat/...) inside the "new scan" block, which runs
after the eye/optics-in and filter-out-of-beam gates. If either gate
declined (e.g. the setup isn't in measurement condition, which disabling
rt feedback can trigger) or the tomo_type-4 angle-file check raised,
tomo_scan() returned/raised having never touched progress, leaving the
GUI/webpage showing projection/angle/start-time from whatever scan last
completed -- arbitrarily old, and easy to mistake for a scan still
running.

Hoists the "is this a new scan" check to the top of tomo_scan() and
calls progress.reset() there, before any gate runs; the heavier new-scan
actions (sample DB registration, PDF report, collect_empty_frames(), the
0-deg reference shot) stay exactly where they were, after the gates.