Merge origin/main into feat/keithley-2400
Brings the LamNI beamtime-2 line (fixes/lamni_during_beamtime_2, contained in
this branch) and the Keithley 2400 work up to main so it can go in by
fast-forward. Conflicts resolved:
- omny_general_tools.py: keep stitch_tile_offsets/lamni_smallest_tile_position_count
  (branch) and read_escape_suffix (main)
- flomni.py: import both helpers; state keeps recent_projection_gaps and tomo_completed
- tomo_params.py: _job_tooltip(job, registry=None, profile=None) combines the
  branch's command-step formatting and main's per-profile field filtering;
  call site passes both by keyword
- test_rt_flomni.py: keep both new tests

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-03 09:25:35 +01:00

114 lines
4.5 KiB
Python

"""Shared bootstrap for constructing a live Flomni against the running sim.
Used both by conftest.py (in-process, section A) and by
_run_queue_subprocess.py (spawned as a separate OS process, section B/C) --
pulled out here so both paths for "build a real Flomni pointed at the sim"
share one definition of what real-instrument setup and side-effect
neutralization is needed. See TOMO_QUEUE_TESTING.md section 3.
Deliberately does NOT call bec.config.load_demo_config()/
update_session_with_file(): assumes the running sim session already has
device_configs/simulated_omny/simulated_bl_simulated_flomni.yaml loaded.
"""
from __future__ import annotations
import builtins
import importlib
from bec_ipython_client import BECIPythonClient
from bec_lib.messaging_services import SciLogMessagingService
from bec_lib.redis_connector import RedisConnector
from bec_lib.service_config import ServiceConfig
from csaxs_bec.bec_ipython_client.plugins.flomni import flomni as flomni_module
from csaxs_bec.bec_ipython_client.plugins.flomni.flomni_webpage_generator import (
FlomniWebpageGenerator,
)
from csaxs_bec.bec_ipython_client.plugins.OMNY_shared.omny_general_tools import OMNYTools
class _NoOpSciLogMessage:
"""Chainable no-op standing in for a real SciLog message object."""
def add_text(self, *a, **k):
return self
def add_tags(self, *a, **k):
return self
def add_attachment(self, *a, **k):
return self
def send(self, *a, **k):
return self
def neutralize_side_effects() -> None:
"""Patch away operator-facing/networked side effects of Flomni().
Plain class-attribute assignment, not pytest's monkeypatch: every
caller (in-process fixture, subprocess script) wants the same patches
for the life of the process, so there's nothing to revert.
- OMNYTools.yesno -> always answers yes, so tomo_queue_execute()'s
confirmation prompt doesn't hang a headless run.
- FlomniWebpageGenerator.start -> no-op. Flomni.__init__ normally starts
this unconditionally, which opens a local HTTP server and spawns
background threads that POST to a real external URL.
- SciLogMessagingService.new -> no-op. tomo_scan() unconditionally sends
a SciLog summary at the end of every scan; SciLog isn't
configured/reachable in this dev environment.
"""
OMNYTools.yesno = lambda self, *a, **k: True
FlomniWebpageGenerator.start = lambda self: None
SciLogMessagingService.new = lambda self, *a, **k: _NoOpSciLogMessage()
def build_flomni(services_config_path):
"""Connect to the already-running sim and return (bec, flomni)."""
config = ServiceConfig(services_config_path)
bec = BECIPythonClient(config, RedisConnector, forced=True, wait_for_server=True)
bec.start()
# flomni.py's module-level `umv` resolves `scans` from the module's own
# globals, populated only by the `if builtins.__dict__.get("bec") is not
# None:` block at import time. Set builtins first, then reload so it
# re-runs (needed even on a fresh process: importing flomni_module above
# ran that block once already, before bec existed).
builtins.__dict__["bec"] = bec
builtins.__dict__["dev"] = bec.device_manager.devices
builtins.__dict__["scans"] = bec.scans
importlib.reload(flomni_module)
builtins.__dict__["umv"] = flomni_module.umv
neutralize_side_effects()
flomni = flomni_module.Flomni(bec)
# RT interferometer feedback + fsamx-in-position setup, mirroring
# Flomni._align_setup(). Only intervene when actually needed: fsamx is
# normally left read_only (locked) by a *previous*
# feedback_enable_with_reset() call (its own last step, so the RT
# controller's PID correction owns fine positioning going forward), and
# a move request against a read_only device raises DisabledDeviceError.
# feedback_enable_with_reset() itself is expensive (re-zeros the
# interferometers) -- skip it entirely if feedback is already running,
# which it normally is after the first caller in a test session sets it
# up (device-server state persists across client (re)connections).
rtx = bec.device_manager.devices.rtx
if not rtx.controller.feedback_is_running():
fsamx = bec.device_manager.devices.fsamx
fsamx_in = fsamx.user_parameter.get("in")
if abs(fsamx.readback.get() - fsamx_in) > 0.3:
fsamx.read_only = False
flomni_module.umv(fsamx, fsamx_in)
flomni.rt_feedback_enable_with_reset()
return bec, flomni
def shutdown(bec) -> None:
bec.shutdown()
bec._client._reset_singleton()