diff --git a/csaxs_bec/devices/jungfraujoch/eiger.py b/csaxs_bec/devices/jungfraujoch/eiger.py index 0d577a7..4ff60a4 100644 --- a/csaxs_bec/devices/jungfraujoch/eiger.py +++ b/csaxs_bec/devices/jungfraujoch/eiger.py @@ -279,18 +279,18 @@ class Eiger(PSIDeviceBase): try: incident_energy = self._get_beam_energy(self.device_manager) if self._incident_energy is None: - self._incident_energy = incident_energy + self._incident_energy = float(round(incident_energy, 3)) elif not np.isclose( self._incident_energy, incident_energy, atol=0.01 ): # 10 keV tolerance logger.warning( f"Incident energy changed from {self._incident_energy} keV to {incident_energy} keV for device {self.name}. " ) - self._incident_energy = incident_energy + self._incident_energy = float(round(incident_energy, 3)) except Exception as e: logger.warning(f"Failed to set up beam energy for {self.name}: {e}") incident_energy = 12.0 # default to 12 keV if error occurs - self._incident_energy = incident_energy + self._incident_energy = float(round(incident_energy, 3)) logger.info(f"Device {self.name} uses incident energy of {incident_energy} keV.")