fix/correct matlab tool name to BEC_ptycho_align in tomo_alignment_scan
The tool is called BEC_ptycho_align now, not SPEC_ptycho_align.m as
the previous docs/comments said -- fixes the references introduced in
the previous commit (12b2538) in lamni.py's docstrings/print message
and the user docs.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
This commit is contained in:
@@ -1069,7 +1069,7 @@ class LamNI(TomoQueueMixin, LamNIAlignmentMixin, LamNIOpticsMixin, LamniGuiTools
|
||||
)
|
||||
|
||||
def write_alignment_scan_numbers(self, first_scan: int) -> None:
|
||||
"""Write the scan-number/angle/offset log consumed by SPEC_ptycho_align.m.
|
||||
"""Write the scan-number/angle/offset log consumed by BEC_ptycho_align.
|
||||
|
||||
Mirrors Flomni.write_alignment_scan_numbers() exactly (same 4-line
|
||||
format), adapted to lamni's own alignment-scan angle set (12 points
|
||||
@@ -1105,7 +1105,7 @@ class LamNI(TomoQueueMixin, LamNIAlignmentMixin, LamNIOpticsMixin, LamniGuiTools
|
||||
Flomni.tomo_alignment_scan()). Collects all scan numbers acquired
|
||||
during the alignment, writes them (with angles and the existing
|
||||
x-ray-eye-fit offset at each angle) to
|
||||
~/data/raw/logs/ptychotomoalign_scannum.txt for SPEC_ptycho_align.m,
|
||||
~/data/raw/logs/ptychotomoalign_scannum.txt for BEC_ptycho_align,
|
||||
prints them, and creates a scilog entry summarising the alignment
|
||||
scan numbers.
|
||||
"""
|
||||
@@ -1145,7 +1145,7 @@ class LamNI(TomoQueueMixin, LamNIAlignmentMixin, LamNIOpticsMixin, LamniGuiTools
|
||||
|
||||
umv(dev.lsamrot, 0)
|
||||
self.OMNYTools.printgreenbold(
|
||||
"\n\nAlignment scan finished. Please run SPEC_ptycho_align and load the new fit"
|
||||
"\n\nAlignment scan finished. Please run BEC_ptycho_align and load the new fit"
|
||||
" by lamni.read_additional_correction()."
|
||||
)
|
||||
|
||||
|
||||
@@ -64,7 +64,7 @@ The sample fine alignment can be obtained using ptychography. For this a short l
|
||||
|
||||
* `lamni.tomo_parameters()` adjust the ptychographic scan parameters for the alignment scan (FOV/step size/counting time) — `tomo_type` and number of projections are ignored, since the alignment scan always runs its own fixed 12 points spread evenly across the full 360 degrees, independent of the main tomogram's settings.
|
||||
* `lamni.tomo_alignment_scan()` perform the alignment scan. Requires x-ray-eye alignment to have already been done — it will abort with a message otherwise. Scan numbers, angles and the existing x-ray-eye-fit offset at each angle are written to `~/data/raw/logs/ptychotomoalign_scannum.txt` and also printed at the end.
|
||||
* Run `SPEC_ptycho_align.m` (in Matlab, **force ptycho=1**, and **correct scan numbers**) using the printed/logged scan numbers.
|
||||
* Run `BEC_ptycho_align` (in Matlab, **force ptycho=1**, and **correct scan numbers**) using the printed/logged scan numbers.
|
||||
* Click the sample position in the Matlab GUI and then load the generated file by, for example
|
||||
`lamni.read_additional_correction('/sls/X12SA/data/e20632/Data10/cxs_software/ptycho/correction_lamni_um_S05389_lamni_fit.txt')`
|
||||
* With this alignment a second iteration could be performed. To read the second correction file use `lamni.read_additional_correction_2()`
|
||||
|
||||
Reference in New Issue