From d04932b68d0225a91489f0f63aa4556f699b4255 Mon Sep 17 00:00:00 2001 From: x01dc Date: Sun, 6 Sep 2026 13:15:11 +0200 Subject: [PATCH] docs(omny): split vision plan into a generic toolkit/interface + confirm app Per feedback: split the design into three layers instead of one confirm-scoring device. Layer 0 is a plain image-manipulation toolkit (grayscale, edge detection, registration, overlays) with no device/BEC dependency. Layer 1 is a new generic VisionInterface device -- camera in, processed image out, mode selectable at runtime -- usable as an in-between interface for any camera consumer, not just sample-transfer confirms; x_ray_eye_align.py's alignment GUI is called out as a second, independent consumer. Layer 2 (SampleVisionMonitor, the sample-transfer confirm/scoring device from the previous pass) is now framed as one application built on top of Layers 0/1. Co-Authored-By: Claude Sonnet 5 Claude-Session: https://claude.ai/code/session_018Mupip8x7Hean6E3FFvpbj --- .../MACHINE_VISION_AUTOCONFIRM_PLAN.md | 159 ++++++++++++------ 1 file changed, 106 insertions(+), 53 deletions(-) diff --git a/csaxs_bec/bec_ipython_client/plugins/omny/AI_docs/MACHINE_VISION_AUTOCONFIRM_PLAN.md b/csaxs_bec/bec_ipython_client/plugins/omny/AI_docs/MACHINE_VISION_AUTOCONFIRM_PLAN.md index 134ae6ba..1e624ba8 100644 --- a/csaxs_bec/bec_ipython_client/plugins/omny/AI_docs/MACHINE_VISION_AUTOCONFIRM_PLAN.md +++ b/csaxs_bec/bec_ipython_client/plugins/omny/AI_docs/MACHINE_VISION_AUTOCONFIRM_PLAN.md @@ -15,8 +15,12 @@ Applied to BEC: could this let OMNY's sample-transfer flow (`otransfer_get_sampl single one, while still catching real problems (pin damage, missed grip, wrong shuttle state)? This doc maps that idea onto OMNY's actual confirm gates and camera/GUI plumbing, and proposes a -staged plan. **Goal for this session: write this plan down. Implementation is a separate, later -branch.** +staged plan. Follow-up feedback broadened the scope: rather than building the image-processing logic +into a single confirm/scoring device, keep it generic — a reusable camera-in/processed-image-out +interface (grayscale, edge detection, overlays, ...) that the sample-transfer confirm use case is +only the *first* consumer of; `x_ray_eye_align.py`'s alignment GUI is identified below as a second, +independent consumer of the same layer. **Goal for this session: write this plan down. +Implementation is a separate, later branch.** ## Where today's human confirmations actually live @@ -80,56 +84,95 @@ post-hoc audit log today, with no comparison logic reading it back. - **`opencv-python`** is already a project dependency (`pyproject.toml:27`); `scikit-image` is not yet (needed only if SSIM specifically is wanted — see below). -## Proposed architecture: a generic, camera-agnostic vision device +## Proposed architecture: a generic, camera-agnostic vision layer Earlier drafts of this plan sketched the CV pipeline as logic living inside `IDSCamera` itself, or inline in `omny_sample_transfer_mixin.py` calling `cv2`/`skimage` directly against whichever -`cam200`-`cam203` frame it just pulled. Mirko's feedback: keep the imaging pipeline generic and -reusable against *any* camera, structured as its own device with a camera as a declared dependency, -rather than building it into a specific camera class. Concretely: +`cam200`-`cam203` frame it just pulled. Mirko's feedback, in two parts: (1) keep the imaging +pipeline generic and reusable against *any* camera, structured as its own device with a camera as a +declared dependency, rather than building it into a specific camera class; (2) go further than a +single-purpose confirm/scoring device — make the underlying image manipulation (grayscale, edge +detection, and similar) a generic, reusable *interface* that can sit between a raw camera and its +consumer for other purposes too, e.g. an alternative processed/overlay view for +`x_ray_eye_align.py`'s alignment GUI, not just sample-transfer scoring. Three layers, each usable on +its own: -- **A new, endstation-agnostic device class** (working name `SampleVisionMonitor`), living outside - `omny/` — e.g. `csaxs_bec/devices/vision/sample_vision_monitor.py` — so it isn't OMNY-specific - code, just OMNY's first user of it. -- **Its only hard dependency is the shared `get_last_image()` contract** above — nothing - `IDSCamera`-specific (no reliance on `push_smear_preview`, the `image` `PreviewSignal`'s - rotation/transpose handling, etc.). Any current or future camera class that implements - `get_last_image() -> np.ndarray | None` can be wired in, including `AlliedVisionAravisCamera` or a - simulated camera, with zero changes to this device. -- **Config-driven camera dependency, resolved lazily.** A `camera_names: list[str]` constructor - parameter (a list, not a single name, so OMNY's camera-*pairs* — `["cam200", "cam203"]` for - parking, `["cam201", "cam202"]` for the sample stage — are a natural fit; a single-camera setup - like flomni's gripper cam is just a length-1 list). Resolved through - `self.device_manager.devices.get(name, None)` at call time, mirroring `ddg_1.py`'s pattern above, - with a clear error if a configured name isn't present in the active session's device config. - **This is what makes the device reusable across endstations without touching its code**: the same - class, pointed at a different `camera_names` list in a different beamline's device-config YAML, - is the entire integration cost for a new camera or a new endstation. -- **Runs device-server-side** (a `PSIDeviceBase` subclass, like `IDSCamera` itself), consistent with - where camera image processing already happens in this codebase, and appropriate for the - registration/scoring compute cost. -- **Opaque, caller-defined reference tags**, not OMNY vocabulary baked into the device: reference - images and scores are grouped by a plain string tag the caller picks (for OMNY, - `f"{step_name}_{pin_position}"`; a different endstation could tag however makes sense to it) — the - device itself has no notion of "pin position" or "shuttle slot". +### Layer 0 — a plain image-processing toolkit (pure functions, no device, no BEC dependency) + +Grayscale conversion, CLAHE, Sobel/Canny edge detection, ECC/ORB-based registration, contour +extraction, and overlay drawing (crosshair, contour outline, diff highlight) as plain +`numpy`/`opencv` functions — array in, array (or array + metadata, e.g. a fitted transform or a +contour) out. No devices, no BEC imports, trivially unit-testable in isolation, matching this +repo's existing preference for pure-function "widget math" test files (e.g. +`test_omny_tomo_params_widget_math.py`). This is the shared vocabulary both layers below build on — +neither the confirm/scoring use case nor a live processed-view use case should each hand-roll their +own edge-detection/registration code. + +### Layer 1 — `VisionInterface`: a generic camera-in, processed-image-out device + +The direct answer to "a camera interface that allows image manipulation... could be used as an +intermediate interface for x_ray_eye align, bypass the normal image, activate edge detection, +overlay graphics": a device that sits *between* a source camera and whatever is watching it, +publishing a transformed view instead of (or alongside) the raw feed. + +- **Endstation-agnostic**, living outside `omny/` — e.g. `csaxs_bec/devices/vision/vision_interface.py`. +- **Same camera-dependency mechanism as before**: config-driven `camera_names: list[str]`, resolved + lazily via `self.device_manager.devices.get(name, None)` (the `ddg_1.py` pattern), requiring only + the shared `get_last_image()` contract — no dependency on which concrete camera class it's pointed + at. +- **A selectable processing mode**, built from Layer 0's toolkit — `"raw"`, `"grayscale"`, + `"edges"`, `"clahe"`, `"overlay"` (e.g. a stored reference's contour drawn over the live frame), + or a small ordered pipeline of these — settable at runtime via an RPC/`Signal` (e.g. + `set_mode(name: str)`), not hardcoded per device instance. This generalizes what + `push_smear_preview()`/the existing `smear_preview_toggle` do today (one hardcoded composite, one + fixed second channel) into "any of a small library of transforms, chosen at runtime". +- **Own `diagnostic_image` `PreviewSignal`**, decoupled from whichever camera it's pointed at (the + "own signal" option from the previous draft of this doc) — this is what makes it a genuine + in-between interface rather than a camera-specific patch: the GUI dock watches the + `VisionInterface`'s output, and swapping/reconfiguring the source camera or the active mode + doesn't change what the dock is looking at. +- **Two independent consumers**, justifying building this generically rather than folding it + straight into the sample-transfer use case: + - **`SampleVisionMonitor`** (Layer 2, below) uses it for registration + the diagnostic overlay it + publishes during confirm gates. + - **`x_ray_eye_align.py`**'s alignment GUI (`update_frame()`, + `flomni/x_ray_eye_align.py:114-135` — the operator watches a raw live `cam_xeye` feed and + manually places alignment points, fit later done in Matlab; OMNY's own copy is still an + unadapted LamNI leftover per `OPEN_ISSUES.md`) currently shows only the unprocessed live image. + A `VisionInterface` in front of `cam_xeye` could offer an edge-enhanced or CLAHE-normalized live + view as an operator-toggleable alternative during manual point-picking — exactly the same + exposure-invariance motivation as the sample-transfer use case, applied to a second, already- + existing manual-confirmation-style workflow. **Not proposed as a replacement for the existing + Matlab-based fit** — just a second real consumer of the same generic layer, and a concrete + illustration of why Layer 0/1 shouldn't be scoped to OMNY sample-transfer specifically. + +### Layer 2 — `SampleVisionMonitor`: the sample-transfer confirm/scoring application + +Everything from the previous draft of this plan, now explicitly framed as *one application built on +top of Layers 0/1*, not a separate camera-coupled implementation: + +- **Runs device-server-side** (a `PSIDeviceBase` subclass, like `IDSCamera`/`VisionInterface` + itself), consistent with where camera image processing already happens in this codebase. +- **Opaque, caller-defined reference tags** — reference images and scores are grouped by a plain + string tag the caller picks (for OMNY, `f"{step_name}_{pin_position}"`); the device itself has no + notion of "pin position" or "shuttle slot". - **Client-facing RPC surface** (sketch, names not final): - - `save_reference(tag: str) -> None` — pulls the current frame(s) from the configured camera(s) - and stores them as a labeled reference under `tag`. - - `score(tag: str) -> dict` — pulls the current frame(s), registers + scores each against every - stored reference under `tag` (see CV pipeline below), publishes a diagnostic overlay (see next - bullet), and returns the best-match score(s) plus enough detail to build a confirm message. + - `save_reference(tag: str) -> None` — pulls the current frame(s) (via its own or a shared + `VisionInterface`) and stores them as a labeled reference under `tag`. + - `score(tag: str) -> dict` — registers + scores the current frame(s) against every stored + reference under `tag` (see CV pipeline below, using Layer 0's registration/contour/SSIM + functions), publishes a diagnostic diff/overlay through the `VisionInterface` it uses, and + returns the best-match score(s) plus enough detail to build a confirm message. - `omny_sample_transfer_mixin.py`'s gates (1-4 above) become *callers* of this device - (`dev.omny_vision_parking.score(...)`, `dev.omny_vision_samplestage.score(...)`, one device - instance per camera pair) instead of doing any `cv2`/`skimage` work themselves — the mixin only - turns the returned score into a confirm-dialog decision (per the staged rollout below). - - **Own diagnostic signal vs. borrowing the target camera's channel** — open decision, not - resolved here: (a) give `SampleVisionMonitor` its own `diagnostic_image` `PreviewSignal` - component, fully decoupled from whichever camera it's pointed at, requiring one new `Image` dock - in `gui_tools.py` per vision device; vs. (b) when the configured camera happens to expose - `push_smear_preview()` (i.e. it's an `IDSCamera`), feature-detect that and reuse the existing - dock + toggle pattern instead of adding a new one. (a) is more genuinely camera-agnostic (matches - the rest of this design); (b) is less new GUI surface for OMNY specifically, at the cost of only - working when the backing camera happens to support it. Worth prototyping both before deciding. + (`dev.omny_vision_parking.score(...)`, `dev.omny_vision_samplestage.score(...)`, one instance + per camera pair) instead of doing any `cv2`/`skimage` work themselves — the mixin only turns the + returned score into a confirm-dialog decision (per the staged rollout below). +- **Open composition question, not resolved here**: whether `SampleVisionMonitor` *contains* a + `VisionInterface` instance internally (composition), or is itself built directly on Layer 0 with + its own separate `diagnostic_image` signal and `VisionInterface` stays a purely GUI/alignment-side + concept. Composition (reusing one `VisionInterface` per camera pair, shared by both the confirm + scoring and any live processed view of that same pair) avoids two devices both owning a signal for + the same physical camera pair — likely the cleaner shape, but worth prototyping both. ## Proposed CV pipeline (classical, no deep learning) @@ -201,13 +244,23 @@ this should not be an all-or-nothing flag flip. Proposed phases for the later im - **Where scores/results live.** Likely alongside the existing HDF5 reference-image files (same per-step file, additional dataset for score + registration transform), rather than a new storage mechanism. -- **Diagnostic visualization: own `PreviewSignal` vs. borrowing the camera's `smear_preview`** — - see the architecture section above; needs a short prototype of both before committing. -- **One `SampleVisionMonitor` config per camera pair vs. one instance whose `camera_names` gets - reconfigured at call time** — static per-pair config (e.g. `omny_vision_parking`, - `omny_vision_samplestage` as two fixed device-config entries) is simpler and matches how OMNY's - own two camera pairs are already fixed, not dynamic; leaning toward this unless a concrete need - for a dynamic pairing shows up. +- **`SampleVisionMonitor` composing a `VisionInterface` vs. owning its own signal directly** — see + the "open composition question" at the end of the architecture section; needs a short prototype of + both before committing. +- **One `SampleVisionMonitor`/`VisionInterface` config per camera pair vs. one instance whose + `camera_names` gets reconfigured at call time** — static per-pair config (e.g. + `omny_vision_parking`, `omny_vision_samplestage` as two fixed device-config entries) is simpler + and matches how OMNY's own two camera pairs are already fixed, not dynamic; leaning toward this + unless a concrete need for a dynamic pairing shows up. +- **How an operator switches `VisionInterface`'s mode from the GUI.** The existing + `smear_preview_toggle` (`x_ray_eye.py:386-873`) is a single on/off switch between two fixed + channels; a `VisionInterface` with several selectable modes (raw/grayscale/edges/CLAHE/overlay) + needs a small mode picker, not just a toggle — new GUI widget surface, not sketched yet. +- **Overlay compositing vs. the GUI's own annotations.** `x_ray_eye_align.py`'s alignment GUI + already lets the operator click to place points/markers on the live image; a `VisionInterface` + "overlay" mode drawing its own graphics (contours, diff highlights) onto the frame it republishes + must not visually conflict with or obscure those widget-drawn markers — needs checking against the + actual widget code before this mode is built, not assumed compatible. ## Non-goals for this session