From 437d9e7559d07b4247d4514c27b35e9d2e99eb68 Mon Sep 17 00:00:00 2001 From: x01dc Date: Thu, 1 Oct 2026 15:11:49 +0200 Subject: [PATCH] feat(flomni): fix tomo-queue move allow-list, drop idgap stub, add foptz+shift action Queue-control "command job" changes: - Remove the "optimize_idgap" stub action (not commissioned, always a no-op) from both Flomni's and LamNI's action registry, and delete the now-dead TomoQueueMixin.optimize_idgap() method. - Fix the "move" action's device allow-list: "mokev" doesn't exist in the current device config at all -- the real energy device is "ccm_energy" (LamNI's copy already had this right). Also drop "ftray" (sample transfer tray), which was only ever there as a sim-testable move target. - Add a new "move_foptz_with_shift" action: moves foptz (the FZP optics-Z stage) and sets the compensating manual_shift_x/manual_shift_y in one atomic step. foptz is deliberately NOT in the plain move allow-list -- moving it shifts the aligned scan center (interferometer mirrors aren't perfectly parallel to the beam), so this is the only way to queue a foptz move, specifically so the compensating shift can never be forgotten. - The foptz target is validated against the device's real, live limits (not a hand-duplicated static number) both in the GUI spinbox's range and in the CLI's add-time validation, so a queued job can't raise when it executes unattended later; a defense-in-depth check also exists at execution time. Retargeted the e2e command-job tests from ftray to foptz (now the only sim-testable move-adjacent path) and updated the AI_docs testing/GUI-testing notes to match the new action set. Also fixes a pre-existing, unrelated broken import (plugins.omny.omny_general_tools -> plugins.OMNY_shared.omny_general_tools, already broken on main) in _bootstrap.py/test_tomo_queue.py/ test_tomo_queue_command_jobs.py that was blocking omny_e2e_tests collection entirely, needed to actually verify this change's own test rewrites. Co-Authored-By: Claude Sonnet 5 Claude-Session: https://claude.ai/code/session_01NPZ9gzN2rt3wgiMnTKyrug --- .../bec_ipython_client/plugins/LamNI/lamni.py | 23 +---- .../plugins/OMNY_shared/tomo_queue_mixin.py | 22 +---- .../flomni/AI_docs/TOMO_QUEUE_GUI_TESTING.md | 43 ++++---- .../flomni/AI_docs/TOMO_QUEUE_TESTING.md | 46 +++++---- .../plugins/flomni/flomni.py | 91 ++++++++++++++--- .../widgets/tomo_params/tomo_params.py | 11 ++- omny_e2e_tests/_bootstrap.py | 2 +- omny_e2e_tests/test_tomo_queue.py | 2 +- .../test_tomo_queue_command_jobs.py | 98 +++++++++++-------- 9 files changed, 208 insertions(+), 130 deletions(-) diff --git a/csaxs_bec/bec_ipython_client/plugins/LamNI/lamni.py b/csaxs_bec/bec_ipython_client/plugins/LamNI/lamni.py index 83def288..24fb1f96 100644 --- a/csaxs_bec/bec_ipython_client/plugins/LamNI/lamni.py +++ b/csaxs_bec/bec_ipython_client/plugins/LamNI/lamni.py @@ -175,9 +175,11 @@ class LamNI(TomoQueueMixin, LamNIAlignmentMixin, LamNIOpticsMixin, LamniGuiTools } # Named-action registry for tomo-queue command jobs -- identical to - # flomni's, since both actions (move, optimize_idgap) are beamline-wide, - # not flomni-specific hardware. See TomoQueueMixin._queue_action_move()/ - # optimize_idgap() for the implementations. + # flomni's plain "move" action, since it's beamline-wide, not + # flomni-specific hardware. flomni also has a "move_foptz_with_shift" + # action for its own FZP optics-Z stage; lamni has no equivalent + # hardware, so it isn't mirrored here. See + # TomoQueueMixin._queue_action_move() for the implementation. _TOMO_QUEUE_ACTIONS = { "move": { "func": "_queue_action_move", @@ -185,21 +187,6 @@ class LamNI(TomoQueueMixin, LamNIAlignmentMixin, LamNIOpticsMixin, LamniGuiTools "help": "Move device(s) to absolute position(s).", "params": {"positions": {"type": "device_positions"}}, }, - "optimize_idgap": { - "func": "optimize_idgap", - "idempotent": True, - "help": "Scan idgap over a search range and move to the peak. STUB: no-op.", - "params": { - "search_range": { - "type": "float", - "default": 0.5, - "min": 0.0, - "max": 2.0, - "unit": "mm", - "label": "Search range", - } - }, - }, } def _describe_tomo_job_line(self, job: dict) -> str: diff --git a/csaxs_bec/bec_ipython_client/plugins/OMNY_shared/tomo_queue_mixin.py b/csaxs_bec/bec_ipython_client/plugins/OMNY_shared/tomo_queue_mixin.py index a3116464..9b80ddc4 100644 --- a/csaxs_bec/bec_ipython_client/plugins/OMNY_shared/tomo_queue_mixin.py +++ b/csaxs_bec/bec_ipython_client/plugins/OMNY_shared/tomo_queue_mixin.py @@ -586,6 +586,11 @@ class TomoQueueMixin: if not isinstance(value, (int, float)) or isinstance(value, bool): raise ValueError(f"{action_name}.{name} must be a number, got {value!r}.") lo, hi = field.get("min"), field.get("max") + device_name = field.get("device_limits_from") + if device_name is not None: + device = self.device_manager.devices.get(device_name) + if device is not None: + lo, hi = device.limits if lo is not None and value < lo: raise ValueError(f"{action_name}.{name}={value} is below the minimum {lo}.") if hi is not None and value > hi: @@ -618,23 +623,6 @@ class TomoQueueMixin: args += [dev[name], target] umv(*args) - def optimize_idgap(self, search_range: float = 0.5) -> None: - """Scan idgap over +/- search_range around its current position and - move to the peak of . - - STUB -- not implemented. The peak-detection signal/device is not yet - decided (see flomni's AI_docs/TOMO_QUEUE_COMMAND_JOBS_PLAN.md section - 10). This is the ONLY place that needs to change to make this a real - action: the registry entry, resume policy, and (eventually) GUI - wiring already treat it as a normal idempotent compound action, so - dropping in the real scan-and-move-to-peak logic here (or swapping - which device/signal it reads) is a self-contained change. - """ - print( - f"optimize_idgap(search_range={search_range}): not yet implemented -- " - "peak-detection signal not yet decided. No-op." - ) - def _describe_tomo_queue_actions(self) -> dict: """Serializable description of the action registry + move allow-list. diff --git a/csaxs_bec/bec_ipython_client/plugins/flomni/AI_docs/TOMO_QUEUE_GUI_TESTING.md b/csaxs_bec/bec_ipython_client/plugins/flomni/AI_docs/TOMO_QUEUE_GUI_TESTING.md index ac1eaa22..e87eb205 100644 --- a/csaxs_bec/bec_ipython_client/plugins/flomni/AI_docs/TOMO_QUEUE_GUI_TESTING.md +++ b/csaxs_bec/bec_ipython_client/plugins/flomni/AI_docs/TOMO_QUEUE_GUI_TESTING.md @@ -41,8 +41,10 @@ support on top of it: registry `Flomni.__init__` publishes) so its action dropdown and per-action fields always match whatever's actually in `flomni.py` — no hardcoded mirror. Lets you add steps in order (action + its own fields - only — a device dropdown and target for `move`, a bounded spinbox for - `optimize_idgap`'s `search_range`), remove a step, reorder steps within + only — a device dropdown and target for `move`, three bounded spinboxes + for `move_foptz_with_shift`'s `foptz_target`/`manual_shift_x`/ + `manual_shift_y`, the first of which ranges over `foptz`'s live device + limits rather than a static number), remove a step, reorder steps within the job (move up/down), and set a label + idempotent flag (defaults to "every step idempotent" ANDed, same as the CLI, until you touch the checkbox yourself). On confirm it produces a job dict byte-for-byte @@ -50,7 +52,8 @@ support on top of it: 2. **Command-job-aware queue table.** `TomoQueueDialog`'s table gained a "Details" column; a command job shows `CMD` in the Type column and its step summary + idempotency marker in Details (e.g. - `move{'positions': {'mokev': 6.2}} > optimize_idgap{'search_range': 0.5} [idem]` + `move{'positions': {'ccm_energy': 6.2}} > move_foptz_with_shift{'foptz_target': + 15.0, 'manual_shift_x': 1.0, 'manual_shift_y': -2.0} [idem]` — literally the same string `flomni.tomo_queue_show()` prints). 3. **Self-describing tomo jobs.** "Add current params to queue" now stamps `"kind": "tomo"` and a fresh `"id"` on the job it writes, matching what @@ -201,19 +204,22 @@ file is exactly how a regression sneaks in. ## 4. Test plan — new: command-job builder 6. Click **"Add command…"**. Confirm the dialog opens with an **action - dropdown showing `move` and `optimize_idgap`** (or whatever's currently - in `flomni.py`'s `_TOMO_QUEUE_ACTIONS` — if you've added a third action - since this was written, it should appear automatically with no GUI - change needed; that's the point of reading the live registry). + dropdown showing `move` and `move_foptz_with_shift`** (or whatever's + currently in `flomni.py`'s `_TOMO_QUEUE_ACTIONS` — if you've added a + third action since this was written, it should appear automatically with + no GUI change needed; that's the point of reading the live registry). 7. With `move` selected, confirm the field area shows a **device dropdown** - (should list `mokev`, `idgap`, `ftray` per the current allow-list) and a - **numeric target field**. Pick a device, set a target, click **"Add - step"**. Confirm a line appears in the step list above, formatted like - `move{'positions': {'mokev': 6.2}}`. -8. Switch the action dropdown to `optimize_idgap`. Confirm the field area - now shows a single **search_range** spinbox pre-filled with `0.5`, - range-limited (try typing outside 0–2, confirm the widget clamps it - rather than accepting it). Click **"Add step"**. + (should list `ccm_energy`, `idgap` per the current allow-list -- `foptz` + is deliberately absent, see point 8) and a **numeric target field**. Pick + a device, set a target, click **"Add step"**. Confirm a line appears in + the step list above, formatted like `move{'positions': {'ccm_energy': 6.2}}`. +8. Switch the action dropdown to `move_foptz_with_shift`. Confirm the field + area now shows three spinboxes: **foptz target (absolute)**, + **Compensating manual_shift_x**, **Compensating manual_shift_y**. Confirm + the foptz-target spinbox's range reflects `foptz`'s *live* device limits + (try typing a value past the real limit, confirm the widget clamps it + rather than accepting it -- this is the live-limit lookup, not a static + number). Fill in all three and click **"Add step"**. 9. Confirm the **idempotent checkbox auto-checked itself** after both adds (both current actions default to idempotent=True). Uncheck it by hand, then add another step — confirm it **stays unchecked** (your override @@ -250,9 +256,10 @@ file is exactly how a regression sneaks in. ## 6. Test plan — mixed queue, end to end 17. Build a small realistic sequence via the GUI only: a tomo job ("Add - current params to queue"), then a command job (e.g. a `move` on - `ftray` if you're on the sim — `mokev`/`idgap` only exist on the real - front-end, see plan section 3.1), then another tomo job. + current params to queue"), then a command job (e.g. a `move_foptz_with_shift` + step if you're on the sim — `ccm_energy`/`idgap` only exist on the real + front-end, `foptz` is the only queue-movable device in the sim config), + then another tomo job. 18. From the CLI, run `flomni.tomo_queue_execute()`. Confirm: the tomo job runs, the command job actually moves the device (check `dev..readback.get()` before/after), and the second tomo job diff --git a/csaxs_bec/bec_ipython_client/plugins/flomni/AI_docs/TOMO_QUEUE_TESTING.md b/csaxs_bec/bec_ipython_client/plugins/flomni/AI_docs/TOMO_QUEUE_TESTING.md index ac1ebee5..bc55b595 100644 --- a/csaxs_bec/bec_ipython_client/plugins/flomni/AI_docs/TOMO_QUEUE_TESTING.md +++ b/csaxs_bec/bec_ipython_client/plugins/flomni/AI_docs/TOMO_QUEUE_TESTING.md @@ -264,8 +264,8 @@ interruptible mid-scan for the crash-resume tests (§4, B5). 10. **✅ Add-time validation rejects bad steps, and rejects them without landing anything in the queue.** `test_add_command_validation_errors`. Unknown action, a device not on the `move` allow-list, an out-of-range/wrong-type - `optimize_idgap.search_range`, and an unknown kwarg are each rejected with the - expected `ValueError`; afterward the queue is confirmed still empty. + `move_foptz_with_shift.foptz_target`, and an unknown kwarg are each rejected + with the expected `ValueError`; afterward the queue is confirmed still empty. 11. **✅ Execution-time allow-list re-check is the real safety boundary.** `test_move_execution_time_allowlist_recheck`. A job with a disallowed device appended directly (bypassing `tomo_queue_add_command`) is refused by @@ -278,10 +278,13 @@ interruptible mid-scan for the crash-resume tests (§4, B5). `test_show_and_webpage_survive_command_job`. A command job (no `params` key) renders its step summary + idempotency marker in both, instead of `KeyError`ing. 14. **✅ Back-compat + real dispatch, combined.** - `test_legacy_job_no_kind_defaults_to_tomo_and_command_moves_ftray`. A `kind`-less + `test_legacy_job_no_kind_defaults_to_tomo_and_command_moves_foptz`. A `kind`-less legacy queue entry still runs as a tomogram; in the same mixed-queue run, a - command job actually moves a device (`ftray`, the sim-testable stand-in for - `mokev`/`idgap` — see the plan doc §3.1) via the real `move` action path. + command job actually moves `foptz` and sets the compensating + `manual_shift_x`/`manual_shift_y` via the real `move_foptz_with_shift` action + path (the only sim-movable path now that `ftray` is no longer in the move + allow-list; `foptz` is also the real device this action exists for, unlike + `ftray`'s old sim-only stand-in role). 15. **✅ Non-idempotent resume prompts exactly once, and respects "no".** `test_non_idempotent_command_resume_prompts`. A command job flagged `idempotent=False`, left `incomplete`, triggers the resume prompt (distinct from @@ -294,13 +297,14 @@ interruptible mid-scan for the crash-resume tests (§4, B5). 16. One queued tomogram end-to-end on the real instrument, to confirm the sim's timing/progress semantics match reality closely enough that resume lands on the right angle. -17. `move` on `mokev`/`idgap` end-to-end — neither device is in the flomni sim - config (see the plan doc §3.1), so Step 2's `move` action itself has only been - sim-exercised via `ftray`, never against the real devices it's actually for. +17. `move` on `ccm_energy`/`idgap` end-to-end — neither device is in the flomni + sim config, so Step 2's `move` action itself has only been sim-exercised via + add-time validation (which doesn't require real movement), never a real + execute() against these two devices. -**Gate:** A–D passed on the sim (16/16 tests total). **Steps 1 and 2 are verified -enough to build Step 3 (the GUI) on.** E remains open, and blocks calling `move` on -`mokev`/`idgap` production-ready. +**Gate:** A–D passed on the sim. **Steps 1 and 2 are verified enough to build +Step 3 (the GUI) on.** E remains open, and blocks calling `move` on +`ccm_energy`/`idgap` production-ready. ### A gotcha found testing Step 2 (not a Step-2 bug) @@ -348,11 +352,14 @@ still just its design. - **Registry entry = 4 things:** bound method name, `idempotent` default, help string, and a **params schema** (possibly empty). - **Result-dependent logic lives INSIDE a named action, never across queue steps.** - E.g. "scan idgap, move to peak" is ONE action (`optimize_idgap`) whose method does - the scan, finds the peak, and moves — *not* three queue steps. The queue therefore - never has to carry runtime values between steps; `kwargs` stays plain JSON. A - compound action may take parameters (e.g. `search_range`), declared in its params - schema like any other. + E.g. a hypothetical "scan idgap, move to peak" action would be ONE action whose + method does the scan, finds the peak, and moves — *not* three queue steps. The + queue therefore never has to carry runtime values between steps; `kwargs` stays + plain JSON. The same "bundle, don't split" idea also applies to a compound action + with no runtime-dependent result but a correctness-critical pairing of writes -- + `move_foptz_with_shift` (moves `foptz` + sets the compensating + `manual_shift_x`/`manual_shift_y` atomically, deliberately not reachable as two + separate steps) is the concrete example currently in the registry. - **Publish the registry via a global var** (`tomo_queue_actions`) on `Flomni.__init__` so the GUI builds its dropdowns/forms from it — no hardcoded mirror to drift (the `QUEUE_PARAM_NAMES` mirror between `flomni.py` and `tomo_params.py` already has this @@ -399,9 +406,10 @@ Guarded against command jobs (`job.get("kind", "tomo") == "tomo"` before touchin ## 6. Open questions for Mirko — all resolved - **The final action set and device allow-list**, see `TOMO_QUEUE_COMMAND_JOBS_PLAN.md` - §10 — `move` + `optimize_idgap` only, `_TOMO_QUEUE_MOVE_DEVICES = {mokev, idgap}`. - One detail (`optimize_idgap`'s peak-detection signal) deferred to the - implementation session, not blocking. + §10 — originally `move` + `optimize_idgap`, `_TOMO_QUEUE_MOVE_DEVICES = {mokev, + idgap}`. Superseded since: `optimize_idgap` was removed (never commissioned, stayed + a no-op stub), `mokev` was fixed to the real device name `ccm_energy`, and a new + `move_foptz_with_shift` action was added (see §4D10/§4D14 above for its tests). - **`_TOMO_QUEUE_PARAM_NAMES` renamed to `_TOMO_SCAN_PARAM_NAMES`** (it reads live properties, not queue state — the old name was misleading). Done in `flomni.py`; the `tomo_params.py` comment referencing it by name was updated too (the diff --git a/csaxs_bec/bec_ipython_client/plugins/flomni/flomni.py b/csaxs_bec/bec_ipython_client/plugins/flomni/flomni.py index 501bc558..d6f4d89a 100644 --- a/csaxs_bec/bec_ipython_client/plugins/flomni/flomni.py +++ b/csaxs_bec/bec_ipython_client/plugins/flomni/flomni.py @@ -4455,14 +4455,15 @@ class Flomni( # Curated allow-list for the "move" queue action -- NOT "any device in # dev". Only devices actually reconfigured between tomograms belong here; # this is the difference between a reconfiguration tool and a remote - # control for the whole endstation. mokev/idgap are real front-end - # devices (bl_frontend.yaml, not the flomni sim config); ftray (sample - # transfer tray, harmless to move, untouched by tomo-scan code) is - # included so the move action has a sim-testable target. + # control for the whole endstation. ccm_energy/idgap are real front-end + # devices (bl_frontend.yaml/bl_optics_hutch.yaml, not the flomni sim + # config). foptz is deliberately NOT here -- it has its own dedicated + # "move_foptz_with_shift" action below so the compensating + # manual_shift_x/y correction can never be forgotten (see that action's + # docstring). _TOMO_QUEUE_MOVE_DEVICES = { - "mokev": {"label": "Energy", "unit": "keV"}, + "ccm_energy": {"label": "Energy", "unit": "keV"}, "idgap": {"label": "Undulator gap", "unit": "mm"}, - "ftray": {"label": "Sample transfer tray (sim-testable)", "unit": "mm"}, } # Named-action registry for tomo-queue command jobs. Each entry maps a @@ -4484,23 +4485,83 @@ class Flomni( "help": "Move device(s) to absolute position(s).", "params": {"positions": {"type": "device_positions"}}, }, - "optimize_idgap": { - "func": "optimize_idgap", - "idempotent": True, - "help": "Scan idgap over a search range and move to the peak. STUB: no-op.", + "move_foptz_with_shift": { + "func": "_queue_action_move_foptz_with_shift", + "idempotent": True, # absolute move + absolute param set, re-runs harmlessly + "help": ( + "Move foptz (FZP optics-Z) to an absolute target and set the " + "compensating manual_shift_x/manual_shift_y in the same step -- " + "changing foptz shifts the aligned scan center, so this is the " + "only way to queue a foptz move." + ), "params": { - "search_range": { + "foptz_target": { "type": "float", - "default": 0.5, + "default": 17.0, "min": 0.0, - "max": 2.0, + "max": 27.0, "unit": "mm", - "label": "Search range", - } + "label": "foptz target (absolute)", + # Live ophyd limits (dev.foptz.limits) are checked at add + # time (CommandJobBuilderDialog._build_field_widget / + # TomoQueueMixin._validate_action_kwargs) and again at + # execution time (_queue_action_move_foptz_with_shift) -- + # min/max above are only the static fallback if the live + # device can't be reached. + "device_limits_from": "foptz", + }, + "manual_shift_x": { + "type": "float", + "default": 0.0, + "min": -10.0, + "max": 10.0, + "unit": "um", + "label": "Compensating manual_shift_x", + }, + "manual_shift_y": { + "type": "float", + "default": 0.0, + "min": -50.0, + "max": 50.0, + "unit": "um", + "label": "Compensating manual_shift_y", + }, }, }, } + def _queue_action_move_foptz_with_shift( + self, foptz_target: float, manual_shift_x: float, manual_shift_y: float + ) -> None: + """Move foptz and set the compensating manual_shift_x/y together. + + foptz changes the FZP-to-sample distance, which shifts the aligned + scan center (interferometer mirrors aren't perfectly parallel to the + beam) -- bundling the compensating shift into this one action is + deliberate: foptz is NOT in _TOMO_QUEUE_MOVE_DEVICES, so this is the + only way to queue a foptz move, precisely so the shift can't be + forgotten. + + FUTURE: manual_shift_x/y could be auto-suggested from a calibration + proportional to the change in foptz, instead of typed in by hand -- + deliberately out of scope here. + + Re-checks foptz's live limits at execution time too (not just add + time, see TomoQueueMixin._validate_action_kwargs) -- the actual + safety boundary, since a value could have arrived via the CLI, + bypassing the add-time check, or the limits could have changed + since the job was queued. + """ + lo, hi = dev.foptz.limits + if not (lo <= foptz_target <= hi): + raise ValueError( + f"Queue move_foptz_with_shift: foptz_target={foptz_target} is " + f"outside foptz's current limits ({lo}, {hi})." + ) + umv(dev.foptz, foptz_target) + self.manual_shift_x = manual_shift_x + self.manual_shift_y = manual_shift_y + def _describe_tomo_job_line(self, job: dict) -> str: """flomni's tomo_queue_show() one-line summary: fov/type/step/ctime/range. diff --git a/csaxs_bec/bec_widgets/widgets/tomo_params/tomo_params.py b/csaxs_bec/bec_widgets/widgets/tomo_params/tomo_params.py index 984a8ee7..7e1e16ae 100644 --- a/csaxs_bec/bec_widgets/widgets/tomo_params/tomo_params.py +++ b/csaxs_bec/bec_widgets/widgets/tomo_params/tomo_params.py @@ -2191,7 +2191,16 @@ class CommandJobBuilderDialog(QDialog): if field_type == "float": w = QDoubleSpinBox() w.setDecimals(4) - w.setRange(field.get("min", -1e9), field.get("max", 1e9)) + lo, hi = field.get("min", -1e9), field.get("max", 1e9) + device_name = field.get("device_limits_from") + if device_name is not None: + device = self._client.device_manager.devices.get(device_name) + if device is not None: + try: + lo, hi = device.limits + except Exception: + pass # fall back to the static schema min/max above + w.setRange(lo, hi) w.setValue(field.get("default", 0.0)) return w if field_type == "device_positions": diff --git a/omny_e2e_tests/_bootstrap.py b/omny_e2e_tests/_bootstrap.py index 40161d81..133d9b4e 100644 --- a/omny_e2e_tests/_bootstrap.py +++ b/omny_e2e_tests/_bootstrap.py @@ -25,7 +25,7 @@ from csaxs_bec.bec_ipython_client.plugins.flomni import flomni as flomni_module from csaxs_bec.bec_ipython_client.plugins.flomni.flomni_webpage_generator import ( FlomniWebpageGenerator, ) -from csaxs_bec.bec_ipython_client.plugins.omny.omny_general_tools import OMNYTools +from csaxs_bec.bec_ipython_client.plugins.OMNY_shared.omny_general_tools import OMNYTools class _NoOpSciLogMessage: diff --git a/omny_e2e_tests/test_tomo_queue.py b/omny_e2e_tests/test_tomo_queue.py index 561791f5..5b2a67ed 100644 --- a/omny_e2e_tests/test_tomo_queue.py +++ b/omny_e2e_tests/test_tomo_queue.py @@ -65,7 +65,7 @@ def test_empty_and_all_done_queue_are_noops(flomni_sim, monkeypatch, capsys): flomni = flomni_sim prompt_calls = [] - from csaxs_bec.bec_ipython_client.plugins.omny.omny_general_tools import OMNYTools + from csaxs_bec.bec_ipython_client.plugins.OMNY_shared.omny_general_tools import OMNYTools monkeypatch.setattr( OMNYTools, "yesno", lambda self, *a, **k: prompt_calls.append((a, k)) or True diff --git a/omny_e2e_tests/test_tomo_queue_command_jobs.py b/omny_e2e_tests/test_tomo_queue_command_jobs.py index dfb3d890..ea2e8554 100644 --- a/omny_e2e_tests/test_tomo_queue_command_jobs.py +++ b/omny_e2e_tests/test_tomo_queue_command_jobs.py @@ -1,10 +1,13 @@ """Step 2 -- command jobs. See AI_docs/TOMO_QUEUE_COMMAND_JOBS_PLAN.md. -mokev/idgap (the real curated move targets) aren't in the flomni sim config -(simulated_flomni.yaml) -- only on the real front end (bl_frontend.yaml), so -the real device-moving path here is exercised against `ftray` (sample -transfer tray), added to _TOMO_QUEUE_MOVE_DEVICES specifically for this -sim-testability, per TOMO_QUEUE_TESTING.md. +ccm_energy/idgap (the plain "move" allow-list) aren't in the flomni sim +config (simulated_flomni.yaml) -- only on the real front end +(bl_frontend.yaml/bl_optics_hutch.yaml). Tests that only exercise add-time +validation/rendering (no tomo_queue_execute()) reference idgap for that +reason, while tests that actually execute the queue use the dedicated +"move_foptz_with_shift" action against foptz, which IS in the sim config +and is the only queue-movable path for foptz (it is deliberately excluded +from the plain "move" allow-list, see flomni.py's _TOMO_QUEUE_MOVE_DEVICES). """ import datetime @@ -13,8 +16,8 @@ import uuid import pytest from _queue_helpers import FAST_STEPSIZE, add_short_job -FTRAY_A = -50.0 -FTRAY_B = -10.0 +FOPTZ_A = 15.0 +FOPTZ_B = 5.0 def test_add_command_validation_errors(flomni_sim): @@ -28,12 +31,18 @@ def test_add_command_validation_errors(flomni_sim): with pytest.raises(ValueError, match="above the maximum"): flomni.tomo_queue_add_command( - {"action": "optimize_idgap", "kwargs": {"search_range": 99.0}} + { + "action": "move_foptz_with_shift", + "kwargs": {"foptz_target": 99.0, "manual_shift_x": 0.0, "manual_shift_y": 0.0}, + } ) with pytest.raises(ValueError, match="must be a number"): flomni.tomo_queue_add_command( - {"action": "optimize_idgap", "kwargs": {"search_range": "wide"}} + { + "action": "move_foptz_with_shift", + "kwargs": {"foptz_target": "far", "manual_shift_x": 0.0, "manual_shift_y": 0.0}, + } ) with pytest.raises(ValueError, match="has no parameter"): @@ -74,23 +83,25 @@ def test_move_execution_time_allowlist_recheck(flomni_sim): def test_tomo_queue_actions_global_var_matches_registry(flomni_sim): flomni = flomni_sim published = flomni.client.get_global_var("tomo_queue_actions") - assert set(published["actions"]) == {"move", "optimize_idgap"} - assert published["move_devices"]["ftray"]["unit"] == "mm" + assert set(published["actions"]) == {"move", "move_foptz_with_shift"} + assert published["move_devices"]["idgap"]["unit"] == "mm" assert published["actions"]["move"]["idempotent"] is True - assert published["actions"]["optimize_idgap"]["params"]["search_range"]["default"] == 0.5 + assert ( + published["actions"]["move_foptz_with_shift"]["params"]["foptz_target"]["default"] == 17.0 + ) def test_show_and_webpage_survive_command_job(flomni_sim, capsys): flomni = flomni_sim flomni.tomo_queue_add_command( - {"action": "move", "kwargs": {"positions": {"ftray": FTRAY_A}}}, - label="move ftray", + {"action": "move", "kwargs": {"positions": {"idgap": 6.0}}}, + label="move idgap", idempotent=True, ) capsys.readouterr() jobs = flomni.tomo_queue_show() out = capsys.readouterr().out - assert "CMD move{'positions': {'ftray': -50.0}}" in out + assert "CMD move{'positions': {'idgap': 6.0}}" in out assert "[idem]" in out assert jobs[0]["kind"] == "command" @@ -100,7 +111,7 @@ def test_show_and_webpage_survive_command_job(flomni_sim, capsys): assert "isCommand" in html # the rendering branch exists; full JS isn't executed here -def test_legacy_job_no_kind_defaults_to_tomo_and_command_moves_ftray(flomni_sim): +def test_legacy_job_no_kind_defaults_to_tomo_and_command_moves_foptz(flomni_sim): """B-style back-compat + the real command-job execution path, combined into one mixed-queue run to keep the (only) real scan in this file to one job. @@ -109,12 +120,12 @@ def test_legacy_job_no_kind_defaults_to_tomo_and_command_moves_ftray(flomni_sim) bec = flomni.client # Start from a known position, not whatever a previous test run happened - # to leave ftray at -- ftray's position is real device-server state that + # to leave foptz at -- foptz's position is real device-server state that # persists across separate pytest invocations, unlike the tomo_queue/ # tomo_progress global vars the flomni_sim fixture snapshots/restores. - flomni._queue_action_move({"ftray": FTRAY_B}) - ftray_before = bec.device_manager.devices.ftray.readback.get() - assert ftray_before == pytest.approx(FTRAY_B) + flomni._queue_action_move_foptz_with_shift(FOPTZ_B, 0.0, 0.0) + foptz_before = bec.device_manager.devices.foptz.readback.get() + assert foptz_before == pytest.approx(FOPTZ_B) add_short_job(flomni, "legacy_tomo", FAST_STEPSIZE) # Simulate a queue entry written before the "kind" field existed. @@ -123,41 +134,48 @@ def test_legacy_job_no_kind_defaults_to_tomo_and_command_moves_ftray(flomni_sim) bec.set_global_var("tomo_queue", jobs) flomni.tomo_queue_add_command( - {"action": "move", "kwargs": {"positions": {"ftray": FTRAY_A}}}, label="move ftray" - ) - flomni.tomo_queue_add_command( - {"action": "optimize_idgap", "kwargs": {"search_range": 0.5}}, label="idgap stub" + { + "action": "move_foptz_with_shift", + "kwargs": {"foptz_target": FOPTZ_A, "manual_shift_x": 1.0, "manual_shift_y": -2.0}, + }, + label="move foptz", ) flomni.tomo_queue_execute() jobs = flomni._tomo_queue_proxy.as_list() - assert [j["status"] for j in jobs] == ["done", "done", "done"] + assert [j["status"] for j in jobs] == ["done", "done"] # Still no "kind" key -- proves it ran (and got marked done) via the # back-compat default, not that execute() silently added one. assert "kind" not in jobs[0] assert "params" in jobs[0] assert jobs[1]["kind"] == "command" - ftray_after = bec.device_manager.devices.ftray.readback.get() - assert ftray_after == pytest.approx(FTRAY_A) - assert ftray_after != pytest.approx(ftray_before) + foptz_after = bec.device_manager.devices.foptz.readback.get() + assert foptz_after == pytest.approx(FOPTZ_A) + assert foptz_after != pytest.approx(foptz_before) + assert flomni.manual_shift_x == pytest.approx(1.0) + assert flomni.manual_shift_y == pytest.approx(-2.0) def test_non_idempotent_command_resume_prompts(flomni_sim, monkeypatch): flomni = flomni_sim bec = flomni.client - ftray = bec.device_manager.devices.ftray + foptz = bec.device_manager.devices.foptz - # Use the same real move path the "move" action itself uses, rather than - # the device's underlying ophyd object directly (ftray's BEC wrapper is - # a Positioner here, unlike fsamx's DeviceBase -- no .obj to reach for). - flomni._queue_action_move({"ftray": FTRAY_B}) - start = ftray.readback.get() - assert start == pytest.approx(FTRAY_B) + # Use the same real move path the "move_foptz_with_shift" action itself + # uses, rather than the device's underlying ophyd object directly + # (foptz's BEC wrapper is a Positioner here, unlike fsamx's DeviceBase -- + # no .obj to reach for). + flomni._queue_action_move_foptz_with_shift(FOPTZ_B, 0.0, 0.0) + start = foptz.readback.get() + assert start == pytest.approx(FOPTZ_B) index = flomni.tomo_queue_add_command( - {"action": "move", "kwargs": {"positions": {"ftray": FTRAY_A}}}, + { + "action": "move_foptz_with_shift", + "kwargs": {"foptz_target": FOPTZ_A, "manual_shift_x": 0.0, "manual_shift_y": 0.0}, + }, label="non-idempotent move", idempotent=False, ) @@ -165,7 +183,7 @@ def test_non_idempotent_command_resume_prompts(flomni_sim, monkeypatch): flomni._tomo_queue_proxy.update_by_id(job_id, status="incomplete") prompts = [] - from csaxs_bec.bec_ipython_client.plugins.omny.omny_general_tools import OMNYTools + from csaxs_bec.bec_ipython_client.plugins.OMNY_shared.omny_general_tools import OMNYTools def _yesno(resume_answer): # tomo_queue_execute()'s own top-level "OK to start?" confirmation @@ -180,11 +198,11 @@ def test_non_idempotent_command_resume_prompts(flomni_sim, monkeypatch): return _fn - # "no" -> must not re-run: ftray stays put, job still ends up "done". + # "no" -> must not re-run: foptz stays put, job still ends up "done". monkeypatch.setattr(OMNYTools, "yesno", _yesno(False)) flomni.tomo_queue_execute() assert len(prompts) == 1 - assert ftray.readback.get() == pytest.approx(start) + assert foptz.readback.get() == pytest.approx(start) assert flomni._tomo_queue_proxy.as_list()[0]["status"] == "done" # Re-arm as incomplete and try again with "yes" -> must re-run. @@ -192,5 +210,5 @@ def test_non_idempotent_command_resume_prompts(flomni_sim, monkeypatch): monkeypatch.setattr(OMNYTools, "yesno", _yesno(True)) flomni.tomo_queue_execute() assert len(prompts) == 2 - assert ftray.readback.get() == pytest.approx(FTRAY_A) + assert foptz.readback.get() == pytest.approx(FOPTZ_A) assert flomni._tomo_queue_proxy.as_list()[0]["status"] == "done"