feat(omny): drop redundant tomo auth code, cap type-3 step at 2.5 deg
CI for csaxs_bec / test (push) Successful in 1m45s
CI for csaxs_bec / test (push) Successful in 1m45s
The "Enter authorization code" (x12sa) prompt gating advanced tomo modes (types 2-5) predates the account-based _SUPERUSER_ACCOUNTS gate added earlier this branch, and is now fully redundant with it -- Mirko asked to remove it. Each mode still prints the existing "significant wear" warning unconditionally instead of only after entering the code. Also added a hard 2.5 degree ceiling on tomo type 3's angular step (golden ratio starting angle mode), replacing its old minimum-100-projections floor with an explicit wear-motivated cap; if the requested projection count implies a larger step, it's clamped down to 2.5 degrees. Type 2's golden_ratio_bunch_size minimum stays at 100 per Mirko's call -- wear avoidance there is handled by the warning message, not a lower floor. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01QLrD7sVYGLAzsQjLVJpCgt
This commit is contained in:
1 parent
bd129b6313
commit
2fbaa6679f
3 files changed
+130
-79
No files matched your search
@@ -244,8 +244,9 @@ def test_tomo_parameters_forces_type_1_for_non_superuser(monkeypatch, fake_bec):
|
||||
|
||||
|
||||
def test_tomo_parameters_allows_superuser_to_unlock_8_subtomo_mode(monkeypatch, fake_bec):
|
||||
"""A superuser account can select and unlock tomo_type 5 (8 sub-tomograms)
|
||||
with the correct authorization code."""
|
||||
"""A superuser account can select and unlock tomo_type 5 (8 sub-tomograms).
|
||||
No authorization code is required -- access is gated purely by the account
|
||||
check (_is_superuser_account()), which is already exercised above."""
|
||||
monkeypatch.setattr(omny_module, "_SUPERUSER_ACCOUNTS", frozenset({"e99999"}))
|
||||
fake_bec.active_account = "e99999" # superuser
|
||||
omny = make_omny()
|
||||
@@ -265,9 +266,9 @@ def test_tomo_parameters_allows_superuser_to_unlock_8_subtomo_mode(monkeypatch,
|
||||
omny.OMNYTools = types.SimpleNamespace(yesno=lambda *a, **k: False)
|
||||
|
||||
# canned answers for: ctime, step, fovx, fovy, stitch_x, stitch_y,
|
||||
# reconstruct_foldername, tomo_type (=5, 8 sub-tomograms), authorization
|
||||
# code, total number of projections
|
||||
canned = iter([1.0, 0.1, 20, 20, 1, 1, "queue", 5, "x12sa", 144])
|
||||
# reconstruct_foldername, tomo_type (=5, 8 sub-tomograms), total number of
|
||||
# projections
|
||||
canned = iter([1.0, 0.1, 20, 20, 1, 1, "queue", 5, 144])
|
||||
monkeypatch.setattr(OMNY, "_get_val", staticmethod(lambda *a, **k: next(canned)))
|
||||
|
||||
omny.tomo_parameters()
|
||||
@@ -275,3 +276,39 @@ def test_tomo_parameters_allows_superuser_to_unlock_8_subtomo_mode(monkeypatch,
|
||||
assert omny.tomo_type == 5
|
||||
# 144 total projections / 8 sub-tomograms -> stepsize 180/(144/8) = 10.0
|
||||
assert omny.tomo_angle_stepsize == pytest.approx(10.0)
|
||||
|
||||
|
||||
def test_tomo_parameters_clamps_type_3_step_size_to_max_2_5_degrees(monkeypatch, fake_bec):
|
||||
"""tomo_type 3 (equally spaced, golden ratio starting angle) enforces a
|
||||
maximum angular step of 2.5 degrees, to limit wear from too many
|
||||
rotations. A superuser requesting too few projections per sub-tomogram
|
||||
(i.e. too large a step) gets clamped down to 2.5 degrees."""
|
||||
monkeypatch.setattr(omny_module, "_SUPERUSER_ACCOUNTS", frozenset({"e99999"}))
|
||||
fake_bec.active_account = "e99999" # superuser
|
||||
omny = make_omny()
|
||||
omny.tomo_countingtime = 1.0
|
||||
omny.tomo_shellstep = 0.1
|
||||
omny.fovx = 20
|
||||
omny.fovy = 20
|
||||
omny.stitch_x = 1
|
||||
omny.stitch_y = 1
|
||||
omny.ptycho_reconstruct_foldername = "queue"
|
||||
omny.tomo_angle_stepsize = 10.0
|
||||
omny.tomo_type = 1
|
||||
fake_dev = types.SimpleNamespace(
|
||||
omny_samples=types.SimpleNamespace(get_sample_name_in_samplestage=lambda: "test_sample")
|
||||
)
|
||||
monkeypatch.setattr(omny_module, "dev", fake_dev, raising=False)
|
||||
omny.OMNYTools = types.SimpleNamespace(yesno=lambda *a, **k: False)
|
||||
|
||||
# canned answers for: ctime, step, fovx, fovy, stitch_x, stitch_y,
|
||||
# reconstruct_foldername, tomo_type (=3), projections per sub-tomogram
|
||||
# (=10 -> would be an 18 degree step, far above the 2.5 degree cap),
|
||||
# stop-after-projections, repeat-at-0-deg
|
||||
canned = iter([1.0, 0.1, 20, 20, 1, 1, "queue", 3, 10, 0, 0])
|
||||
monkeypatch.setattr(OMNY, "_get_val", staticmethod(lambda *a, **k: next(canned)))
|
||||
|
||||
omny.tomo_parameters()
|
||||
|
||||
assert omny.tomo_type == 3
|
||||
assert omny.tomo_angle_stepsize == pytest.approx(2.5)
|
||||
Reference in new issue