updated documentation
This commit is contained in:
BIN
doc/musrSim.pdf
BIN
doc/musrSim.pdf
Binary file not shown.
@ -35,14 +35,17 @@ $^3$ ISIS Facility, Rutherford Appleton Laboratory, Chilton, Oxon OX11 0QX, U.K.
|
|||||||
%E-mail: ksedlak@fzu.cz}
|
%E-mail: ksedlak@fzu.cz}
|
||||||
|
|
||||||
\maketitle
|
\maketitle
|
||||||
|
\footnotesize
|
||||||
|
\begin{center}
|
||||||
|
PSI, August 12th, 2016
|
||||||
|
\end{center}\vspace{2mm}
|
||||||
|
\normalsize
|
||||||
\abstracts{
|
\abstracts{
|
||||||
``musrSim'' is a simulation program based on Geant4,
|
``musrSim'' is a simulation program based on Geant4,
|
||||||
optimised for the $\mu$SR instruments.
|
optimised for the $\mu$SR instruments.
|
||||||
This document describes some of the commands used in the user macros
|
This document describes some of the commands used in the user macros
|
||||||
of the simulation program for the $\mu$SR instruments based on the {\sc
|
of the simulation program for the $\mu$SR instruments based on the {\sc
|
||||||
Geant4}. The root output variables are also described.
|
Geant4}. The root output variables are also described.}
|
||||||
}
|
|
||||||
|
|
||||||
%========================================================================================================
|
%========================================================================================================
|
||||||
\section{Scope of the musrSim program}
|
\section{Scope of the musrSim program}
|
||||||
@ -587,6 +590,21 @@ care.
|
|||||||
Switches off the statistical fluctuations in the ionisation losses. Can be usefull
|
Switches off the statistical fluctuations in the ionisation losses. Can be usefull
|
||||||
for some technical studies. Presently works only for \emph{G4eIonisation} and
|
for some technical studies. Presently works only for \emph{G4eIonisation} and
|
||||||
for \emph{G4MuIonisation}.
|
for \emph{G4MuIonisation}.
|
||||||
|
\end{description}
|
||||||
|
|
||||||
|
\noindent For the interaction of keV $\mu^+$ with nanometer-thin carbon foils -- as they are used in the
|
||||||
|
low-energy $\mu^+$ beam line and spectrometer (LEM) at PSI -- two special processes have been
|
||||||
|
defined:
|
||||||
|
\begin{description}
|
||||||
|
\item{\bf /musr/command process addProcess mu+ musrMuFormation -1 -1 2}\\
|
||||||
|
Mu formation: yield function as well as the parameters are taken from: M. Gonin, R. Kallenbach, P. Bochsler: "Charge exchange of hydrogen atoms in carbon foils at 0.4 - 120 keV", Rev.Sci.Instrum. 65 (3), March 1994.
|
||||||
|
|
||||||
|
\item{\bf /musr/command process addProcess mu+ musrMuEnergyLossLandau -1 -1 1}
|
||||||
|
\item{\bf /musr/command SetLandauMPV 0.01}
|
||||||
|
\item{\bf /musr/command SetLandauSigma 0.2}\\
|
||||||
|
This adds to any enabled G4 energy loss process a Landau distribution with most-probable-value
|
||||||
|
\emph{SetLandauMPV} (keV), and width \emph{SetLandauSigma} (keV).
|
||||||
|
|
||||||
|
|
||||||
% There is one special process, combined from G4MultipleScattering and G4CoulombScattering,
|
% There is one special process, combined from G4MultipleScattering and G4CoulombScattering,
|
||||||
% defined by the following command:\\
|
% defined by the following command:\\
|
||||||
|
Reference in New Issue
Block a user