# This is a comment # Script: sigmaSC-vs-temp.txt loadPath ./ load YBCO-40nm-FC-E3p8keV-B10mT-Tscan.db # collection 0 load YBCO-40nm-FC-E3p8keV-B150mT-Tscan.db # collection 1 # B=10mT var SigmaSC_10 = pow(abs(pow($Sigma,2.0)-pow(0.11,2.0)), 0.5) # 0.11 (1/us) is the nuclear contribution (T>Tc) var SigmaSC_10Err = pow(pow($Sigma*$SigmaErr,2.0)+pow(0.11*0.0025,2.0), 0.5)/$SigmaSC_10 # B=150mT var SigmaSC_150 = pow(abs(pow($Sigma,2.0)-pow(0.075,2.0)), 0.5) # 0.075 (1/us) is the nuclear contribution (T>Tc) var SigmaSC_150Err = pow(pow($Sigma*$SigmaErr,2.0)+pow(0.075*0.0025,2.0), 0.5)/$SigmaSC_150 # link variables to collections col 0 : SigmaSC_10 # error variable SigmaSC_10Err doesn't need to be given, it is automatically linked to SigmaSC_10 col 1 : SigmaSC_150 norm select 0 x dataT y SigmaSC_10 select 1 x dataT y SigmaSC_150 savePath ./ plot SigmaSCVsTemp.pdf macro SigmaSCVsTemp.C # end