# This is a comment
# Script: sigmaSC-vs-temp.txt

loadPath ./

load YBCO-40nm-FC-E3p8keV-B10mT-Tscan.db  # collection 0
load YBCO-40nm-FC-E3p8keV-B150mT-Tscan.db # collection 1

# B=10mT
var SigmaSC_10 = pow(abs(pow($Sigma,2.0)-pow(0.11,2.0)), 0.5) # 0.11 (1/us) is the nuclear contribution (T>Tc)
var SigmaSC_10Err = pow(pow($Sigma*$SigmaErr,2.0)+pow(0.11*0.0025,2.0), 0.5)/$SigmaSC_10
# B=150mT
var SigmaSC_150 = pow(abs(pow($Sigma,2.0)-pow(0.075,2.0)), 0.5) # 0.075 (1/us) is the nuclear contribution (T>Tc)
var SigmaSC_150Err = pow(pow($Sigma*$SigmaErr,2.0)+pow(0.075*0.0025,2.0), 0.5)/$SigmaSC_150

# link variables to collections
col 0 : SigmaSC_10    # error variable SigmaSC_10Err doesn't need to be given, it is automatically linked to SigmaSC_10
col 1 : SigmaSC_150

norm

select 0
x dataT
y SigmaSC_10

select 1
x dataT
y SigmaSC_150

savePath ./
plot SigmaSCVsTemp.pdf

macro SigmaSCVsTemp.C

# end