596 Commits

Author SHA1 Message Date
2a4a8738b5 add all simulation results needed to produce hazard scenario graphics 2025-01-09 10:37:28 +01:00
be9aea3abd Sample beam with GGG 2025-01-08 21:43:22 +01:00
18d4e890c5 Sample source with Cd sample 2025-01-08 15:38:43 +01:00
2bc10e5503 Sample source with water sample 2025-01-08 15:37:25 +01:00
7b8aa27940 Sample source for open beam 2025-01-08 15:35:47 +01:00
b5106c9e34 B-Al absorber at MF 2025-01-08 14:45:20 +01:00
552981d726 Cadium mask at MF 2025-01-08 14:43:34 +01:00
cf23a0cdeb Incoherent scatterer at middle focus 2025-01-08 14:40:20 +01:00
f199ce3f3c Beam from shutter with polarizer inserted 2025-01-07 13:30:55 +01:00
3056b20f42 Cold neutrons on shutter 2025-01-07 13:22:22 +01:00
e10e0c15f1 Selene 1 gammas with shutter closed 2025-01-07 13:21:31 +01:00
ed90fdd084 Fast neutrons from RSSA with shutter closed 2025-01-07 13:19:08 +01:00
00475f70fa Run fast neutron from RSSA, shutter open 2025-01-07 09:51:50 +01:00
e90c8ac470 Gammas Selene 1 2025-01-07 09:22:50 +01:00
9eebf1f13f Run Selene 2 gammas 2025-01-06 17:10:33 +01:00
443c1f4dc5 Implement hole in cabinet wall and run on mcc200 2025-01-06 16:59:12 +01:00
fc4b141804 Add new python script and update plot_tally.py 2025-01-06 13:35:21 +01:00
ed4259833e Update to new concept with full width concrete wall at S1 access 2024-01-19 12:14:52 +01:00
7540d585c8 Better statistics 2023-11-07 15:33:20 +01:00
6bad2af68d change up-stream skadi wall to pure concrete skadi_update_v1 2023-11-07 13:59:03 +01:00
b608e63233 add result of last simulation 2023-10-06 09:01:43 +02:00
c8cfc5d6ca Cd sample 2023-10-05 18:04:11 +02:00
897610ed46 Beam on water sample 2023-10-05 09:45:46 +02:00
19d312050b add calculation results so far 2023-10-05 08:53:54 +02:00
b6e4a05c1a B4C at MF 2023-10-04 16:12:05 +02:00
fab3911674 Cd at middle focus 2023-10-04 13:23:15 +02:00
5396bf8b9f MF with installed polarizer 2023-10-04 11:39:33 +02:00
30a79ac61b Change to incoherent scatterer at MF scenario 2023-10-03 14:20:37 +02:00
d244f855b9 Change to SD225 material for wall 2023-10-03 13:40:48 +02:00
65a1efd75f Update wall material to LB235 2023-10-02 17:48:30 +02:00
5563c4a198 Gammas Selene 2 2023-08-31 14:21:18 +02:00
ecc2cc47fe Vanadium at MF 2023-08-31 14:16:36 +02:00
559166763d Test MF incoherent sample 2023-08-31 14:00:03 +02:00
10ab4b20bc MShield brick wall towards racks E01 brick_wall_v1 2023-08-31 13:26:50 +02:00
d43c3d0284 Add results from wall calculations 2023-03-17 09:00:39 +01:00
4b23d23d7c Add a beamstop on the down-stream wall 2023-03-16 10:30:24 +01:00
c739bd7628 Run the sample source without sample to simulate beam on wall scenario 2023-03-15 16:47:16 +01:00
a8b4c84b0b Replace 2cm steel by 10cm concrete wall 2023-03-15 10:16:31 +01:00
98834ad613 Add a thin steel wall on E01 side to allow closer placement of cabinets 2023-03-14 16:58:25 +01:00
b844715acc add results 2023-03-14 12:51:37 +01:00
a10571f221 Add Mirrobor next to Selene 2 and run water again 2022-12-02 15:16:01 +01:00
74278111e6 Add results of simulations 2022-12-02 08:53:32 +01:00
98d7547454 Run GGG sample 2022-12-01 15:28:55 +01:00
097d2e8e5a Run water sample 2022-12-01 15:26:56 +01:00
71fd782efd Run Cadmium sample cave_final_v2 2022-12-01 15:22:36 +01:00
57dd5093dd Fix number of cells and run quick test 2022-12-01 12:53:17 +01:00
83c7c922f7 Concrete density form MShield and add crane pillar 2022-12-01 12:47:06 +01:00
69ccade308 Include MShield information on gaps and feedthrough opening 2022-12-01 11:13:31 +01:00
7a494ed330 Run Cd sample with full statistics 2022-11-30 15:31:20 +01:00
681dbfe9fd Fix used tally and reduce event number 2022-11-30 15:10:23 +01:00