"""EvrOutput._resolve_pulser: an out-of-range pulser number is routine IOC state (an unwired output), not a per-output failure. `init_all()` on the real Bernina EVR0 hits this on a few dozen outputs at once, all wired to the sentinel 65535 -- see the module docstring in `eco.timing.event_timing_new_new`. Two things follow from that being routine: the message should not be shown by default (WARNING -> DEBUG, matching the "unconfigured slot" treatment in `MasterEventSystem._get_slot_codes`), and it should not cost a fresh `DummyPulser` (eight `AdjustableMemory` children) per occurrence -- one shared, lazily-built instance is enough. """ import logging import pytest evt = pytest.importorskip("eco.timing.event_timing_new_new") @pytest.fixture(autouse=True) def _reset_shared_dummy(monkeypatch): monkeypatch.setattr(evt, "_shared_dummy_pulser", None) def _make_output(monkeypatch, number=65535): monkeypatch.setattr( evt, "read_pv_value", lambda *a, **k: number ) output = evt.EvrOutput.__new__(evt.EvrOutput) output.name = "output_test" output.pv_base = "TEST:Output" output._pulsers = [object() for _ in range(24)] return output def test_out_of_range_pulser_returns_the_shared_dummy(monkeypatch): output_a = _make_output(monkeypatch) output_b = _make_output(monkeypatch) pulser_a = output_a._resolve_pulser(None, "pulserA") pulser_b = output_b._resolve_pulser(None, "pulserB") assert isinstance(pulser_a, evt.DummyPulser) assert pulser_a is pulser_b, "one shared instance, not one per output" assert pulser_a is evt._get_shared_dummy_pulser() def test_out_of_range_pulser_is_not_shown_by_default(monkeypatch, caplog): output = _make_output(monkeypatch) with caplog.at_level(logging.WARNING, logger=evt.__name__): output._resolve_pulser(None, "pulserA") assert caplog.text == "", "should be invisible at the default log level" with caplog.at_level(logging.DEBUG, logger=evt.__name__): output._resolve_pulser(None, "pulserA") assert "does not address any of the" in caplog.text