diff --git a/pipelines/actris_header/JFJ_ACSM_017.actris_header b/pipelines/actris_header/JFJ_ACSM_017.actris_header new file mode 100644 index 0000000..d701cc5 --- /dev/null +++ b/pipelines/actris_header/JFJ_ACSM_017.actris_header @@ -0,0 +1,72 @@ +${header_size} 1001 +${originator_name}; Brem, Benjamin; Gysel-Beer, Martin +${lab}, Paul Scherrer Institute, PSI,,,, 5232, Villigen PSI, Switzerland +Nowak, Nora +GAW-WDCA EMEP CREATE ACTRIS +1 1 +${start_day} ${rev_day} +${dt} +Days from the file reference point (start_time) +${nvars} +${scale_factors} +${vars_fill} +end_time of measurement, days from the file reference point +${vars_long_name} +0 +${nlines_aux_com} +Data definition: EBAS_1.1 +Set type code: ${set_type_code} +Station code: ${station} +Platform code: ${platform} +Timezone: UTC +Startdate: ${start_time} +Timeref: 00_00 +Revision date: ${prod_time} +Component: ${component} +Unit: ${unit} +Matrix: ${matrix} +Period code: ${period_tag} +Resolution code: ${dt_tag} +Sample duration: ${dt_tag} +Laboratory code: ${lab} +Instrument type: ${instrument} +Instrument manufacturer: ${brand} +Instrument model: ${model} +Instrument name: ${instr_name} +Instrument serial number: ${sn} +Method ref: ${method_ref} +Orig. time res.: ${dt_raw_tag} +File name: ${fname} +Station WDCA-ID: ${wdca_id} +Station name: ${site} +Station GAW-Name: ${site} +Station GAW-ID: ${gaw_id} +Measurement latitude: ${latitude} +Measurement longitude: ${longitude} +Measurement altitude: ${altitude}m +Station land use: ${wmo_land_use} +Station setting: ${wmo_setting} +Station GAW type: ${gaw_type} +Station WMO region: ${wmo_region} +Originator: ${originator} +Originator: Brem, Benjamin, benjamin.brem@psi.ch, Paul Scherrer Institute, PSI, Laboratory of Atmospheric Chemistry,,, 5232, Villigen PSI, Switzerland +Originator: Gysel-Beer, Martin, martin.gysel@psi.ch, Paul Scherrer Institute, PSI, Laboratory of Atmospheric Chemistry,,, 5232, Villigen PSI, Switzerland +Submitter: ${submitter} +Data level: ${lvl} +Version: 1 +Version description: initial revision +Measurement height: 2m +Inlet type: Hat or hood +Inlet description: Heated total aerosol inlet (25 degC), collects aerosols and hydrometeors smaller than 40 micrometers +Humidity/temperature control: Temperature conditioning at 25 deg. C +Humidity/temperature control description: Sample dried to below 20% RH due to the heated inlet +Volume std. temperature: ${std_temp}K +Volume std. pressure: ${std_pres}hPa +Measurement uncertainty: 0.2 ug/m3 +Measurement uncertainty expl.: includes statistical uncertainty of individual sample and calibration uncertainty +Zero/negative values code: Zero/negative possible +Zero/negative values: Zero and neg. values may appear due to statistical variations at very low concentrations +Standard method: None +Comment: The data has been processed in Tofware and R. A constant CE of 1 has been applied. Acquisition temperature = 298.15 K, acquisition pressure = 650 hPa, STP correction applied with these fixed values. +Acknowledgement: For using this data for any kind of publications, you must contact the data originator(s), in terms of acknowledgment +start_time end_time ${vars_tag} diff --git a/pipelines/actris_header/PAY_ACSM_092.actris_header b/pipelines/actris_header/PAY_ACSM_092.actris_header new file mode 100644 index 0000000..1e52128 --- /dev/null +++ b/pipelines/actris_header/PAY_ACSM_092.actris_header @@ -0,0 +1,72 @@ +${header_size} 1001 +${originator_name}; Brem, Benjamin; Gysel-Beer, Martin +${lab}, Paul Scherrer Institute, PSI,,,, 5232, Villigen PSI, Switzerland +Nowak, Nora +GAW-WDCA EMEP CREATE ACTRIS +1 1 +${start_day} ${rev_day} +${dt} +Days from the file reference point (start_time) +${nvars} +${scale_factors} +${vars_fill} +end_time of measurement, days from the file reference point +${vars_long_name} +0 +${nlines_aux_com} +Data definition: EBAS_1.1 +Set type code: ${set_type_code} +Station code: ${station} +Platform code: ${platform} +Timezone: UTC +Startdate: ${start_time} +Timeref: 00_00 +Revision date: ${prod_time} +Component: ${component} +Unit: ${unit} +Matrix: ${matrix} +Period code: ${period_tag} +Resolution code: ${dt_tag} +Sample duration: ${dt_tag} +Laboratory code: ${lab} +Instrument type: ${instrument} +Instrument manufacturer: ${brand} +Instrument model: ${model} +Instrument name: ${instr_name} +Instrument serial number: ${sn} +Method ref: ${method_ref} +Orig. time res.: ${dt_raw_tag} +File name: ${fname} +Station WDCA-ID: ${wdca_id} +Station name: ${site} +Station GAW-Name: ${site} +Station GAW-ID: ${gaw_id} +Measurement latitude: ${latitude} +Measurement longitude: ${longitude} +Measurement altitude: ${altitude}m +Station land use: ${wmo_land_use} +Station setting: ${wmo_setting} +Station GAW type: ${gaw_type} +Station WMO region: ${wmo_region} +Originator: ${originator} +Originator: Brem, Benjamin, benjamin.brem@psi.ch, Paul Scherrer Institute, PSI, Laboratory of Atmospheric Chemistry,,, 5232, Villigen PSI, Switzerland +Originator: Gysel-Beer, Martin, martin.gysel@psi.ch, Paul Scherrer Institute, PSI, Laboratory of Atmospheric Chemistry,,, 5232, Villigen PSI, Switzerland +Submitter: ${submitter} +Data level: ${lvl} +Version: 1 +Version description: initial revision +Measurement height: 4m +Inlet type: Hat or hood +Inlet description: PM10 inlet (Digitel), collects aerosols and hydrometeors smaller than 10 micrometers +Humidity/temperature control: Temperature conditioning at 25 deg. C +Humidity/temperature control description: Sample dried to below 40% RH due to nafion dryer +Volume std. temperature: ${std_temp}K +Volume std. pressure: ${std_pres}hPa +Measurement uncertainty: 0.2 ug/m3 +Measurement uncertainty expl.: includes statistical uncertainty of individual sample and calibration uncertainty +Zero/negative values code: Zero/negative possible +Zero/negative values: Zero and neg. values may appear due to statistical variations at very low concentrations +Standard method: None +Comment: The data has been processed in Tofware and R. A constant CE of 0.5 has been applied. Acquisition temperature = 296.15 K, acquisition pressure = 960 hPa, STP correction applied with these fixed values. +Acknowledgement: For using this data for any kind of publications, you must contact the data originator(s), in terms of acknowledgment +start_time end_time ${vars_tag}