${header_size} 1001 ${originator_name}; Brem, Benjamin; Gysel-Beer, Martin ${lab}, Paul Scherrer Institute, PSI,,,, 5232, Villigen PSI, Switzerland ${submitter_name} GAW-WDCA EMEP CREATE ACTRIS 1 1 ${start_day} ${rev_day} ${dt} Days from the file reference point (start_time) ${nvars} ${scale_factors} ${vars_fill} end_time of measurement, days from the file reference point ${vars_long_name} 0 ${nlines_aux_com} Data definition: EBAS_1.1 Set type code: ${set_type_code} Station code: ${station} Platform code: ${platform} Timezone: UTC Startdate: ${start_time} Timeref: 00_00 Revision date: ${prod_time} Component: ${component} Unit: ${unit} Matrix: ${matrix} Period code: ${period_tag} Resolution code: ${dt_tag} Sample duration: ${dt_tag} Laboratory code: ${lab} Instrument type: ${instrument} Instrument manufacturer: ${brand} Instrument model: ${model} Instrument name: ${instr_name} Instrument serial number: ${sn} Method ref: ${method_ref} Orig. time res.: ${dt_raw_tag} File name: ${fname} Station WDCA-ID: ${wdca_id} Station name: ${site} Station GAW-Name: ${site} Station GAW-ID: ${gaw_id} Measurement latitude: ${latitude} Measurement longitude: ${longitude} Measurement altitude: ${altitude}m Station land use: ${wmo_land_use} Station setting: ${wmo_setting} Station GAW type: ${gaw_type} Station WMO region: ${wmo_region} Originator: ${originator} Originator: Brem, Benjamin, benjamin.brem@psi.ch, Paul Scherrer Institute, PSI, Laboratory of Atmospheric Chemistry,,, 5232, Villigen PSI, Switzerland Originator: Gysel-Beer, Martin, martin.gysel@psi.ch, Paul Scherrer Institute, PSI, Laboratory of Atmospheric Chemistry,,, 5232, Villigen PSI, Switzerland Submitter: ${submitter} Data level: ${lvl} Version: 1 Version description: initial revision Measurement height: 2m Inlet type: Hat or hood Inlet description: Heated total aerosol inlet (25 degC), collects aerosols and hydrometeors smaller than 40 micrometers Humidity/temperature control: Temperature conditioning at 25 deg. C Humidity/temperature control description: Sample dried to below 20% RH due to the heated inlet Volume std. temperature: ${std_temp}K Volume std. pressure: ${std_pres}hPa Measurement uncertainty: 0.2 ug/m3 Measurement uncertainty expl.: includes statistical uncertainty of individual sample and calibration uncertainty Zero/negative values code: Zero/negative possible Zero/negative values: Zero and neg. values may appear due to statistical variations at very low concentrations Standard method: None Comment: The data has been processed in Tofware and R. A constant CE of 1 has been applied. Acquisition temperature = 298.15 K, acquisition pressure = 650 hPa, STP correction applied with these fixed values. Acknowledgement: For using this data for any kind of publications, you must contact the data originator(s), in terms of acknowledgment start_time end_time ${vars_tag}