Linear-stage Characterization Transfer Package
This package contains the reusable report workflow only. It contains no project evidence, generated report, agent-populated values, or dependency cache.
- Copy the contents of this folder to the root of a new project.
- Place new-project evidence in the empty
ECMC,Encoder,Motor,Measurements,Measurement_System, andMediafolders. Keep evidence filenames unchanged. Keep designs and build records for FAT fixtures or adapters inMechanics. This folder is not a report input. - Complete the editable project fields and checklist responses in
FAT_Checklist.xlsx. - Populate
Report/python_script/Agent_Report_Data.jsononly with values supported by new-project evidence, giving each populated field its source path underfield_sources. Use concise source facts in displayed values; keep evidence comments and qualifications out of report table cells. FollowReport_Input_Manifest.json. A legible, unambiguous photograph inMediais valid evidence for the directly visible component or instrument information permitted by that manifest; cite the exact image path. - Ensure
uvis installed and on PATH. RunEdit_Characterization_Report.batto review and edit report, workbook, and document values in a table. The checklist rows are read only in the app. SelectSave changes, thenCreate working draft PDF. The original batch launcher remains available.
The generator expects images named I1 through I6 in Media and appends
every top-level PDF in Measurements in filename order.